Background And Study Aim: Advanced endoscopic imaging has revolutionized the characterization of lesions during colonoscopy. The aim of this study was to create a new classification for differentiating subcentimetric hyperplastic and adenomatous polyps, and deeply invasive malignant lesions using blue-light imaging (BLI) with high definition, with and without optical magnification, as well as to assess its interobserver concordance.

Methods: A video library consisting of 48 videos/still images (with/without optical magnification) from 24 histologically verified polyps/cancer with BLI was prospectively created. In the first step, seven endoscopists with experience in electronic chromoendoscopy reviewed 12 BLI videos/still images with/without magnification representative of the different histotypes, and individually identified possible descriptors. In the second step, these descriptors were categorized and summarized with a modified Delphi methodology. In the third step, the seven endoscopists independently reviewed the remaining 36 videos/still images with/without optical magnification, and the interobserver agreement for the new descriptors was assessed. The interobserver agreement between endoscopists was assessed using Gwet's AC1.

Results: By reviewing the initial 12 videos/still images, 43 descriptors were proposed. By a modified Delphi process, the endoscopists eventually agreed on summarizing 12 descriptors into three main domains. The main domains identified were: polyp surface (mucus, yes/no; regular/irregular; [pseudo]depressed, yes/no), pit appearance (featureless, yes/no; round/nonround with/without dark spots; homogeneous/heterogeneous distribution with/without focal loss), and vessels (present/absent, lacy, pericryptal, irregular). Interobserver agreement for the polyp surface domain appeared to be almost perfect for mucus (AC1 0.92 with and 0.88 without optical magnification), substantial for the regular/irregular surface (AC1 0.67 with and 0.66 without optical magnification). For the pit appearance domain, interobserver agreement was good for featureless (AC1 0.9 with and 0.8 without optical magnification), and round/nonround (AC1 0.77 with and 0.69 without optical magnification) descriptors, but less consistent for the homogeneity of distribution (AC1 with/without optical magnification 0.58). Agreement was almost perfect for the vessel domain (AC1 0.81 - 0.85).

Conclusions: The new BASIC classification takes into account both morphological features of the polyp, as well as crypt and vessel characteristics. A high concordance among the observers was shown for most of the summarized descriptors. Optical magnification had a beneficial effect in terms of interobserver agreement for most of the descriptors.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0043-121570DOI Listing

Publication Analysis

Top Keywords

optical magnification
36
interobserver agreement
20
videos/still images
16
images with/without
12
with/without optical
12
magnification
10
optical
9
step endoscopists
8
descriptors
8
modified delphi
8

Similar Publications

Deep learning-enabled filter-free fluorescence microscope.

Sci Adv

January 2025

Engineering Research Center of Optical Instrument and System, the Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China.

Optical filtering is an indispensable part of fluorescence microscopy for selectively highlighting molecules labeled with a specific fluorophore and suppressing background noise. However, the utilization of optical filtering sets increases the complexity, size, and cost of microscopic systems, making them less suitable for multifluorescence channel, high-speed imaging. Here, we present filter-free fluorescence microscopic imaging enabled with deep learning-based digital spectral filtering.

View Article and Find Full Text PDF

Background: The Senhance digital laparoscopic system (Senhance) is a surgical robot approved for use in Japan after the da Vinci system. Our institution was the first to introduce this system, which has been used primarily for gastrointestinal surgery. Featuring tactile feedback, eye-movement-controlled camera operation, stereoscopic vision, and magnification, the short-term postoperative outcomes of the Senhance in abdominal surgery have been documented.

View Article and Find Full Text PDF

A Shape-Memory and Durable Transparent Polyacrylate Film Integrated by Soft-Rigid Chains.

Chemistry

December 2024

Hebei University, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Chemical Biology of Hebei Province, College of Chemistry and Materials Science,, CHINA.

Flexible film in display requires multi-functional integration, such as stretchability, flexibility, abrasion resistance, transparency, and shape memory. In this paper, a reasonable design strategy of flexible polyacrylate (PA) film with high transparency, shape memory, excellent abrasion resistance and foldability is presented. The PA films are prepared by free radical polymerization of vinyl-terminated polyurethane (PU) prepolymer as a cross-linking agent and acrylate monomers in ultraviolet (UV) light.

View Article and Find Full Text PDF

Two Hundred Nanometer Thin Multifocal Graphene Oxide Metalens for Varying Magnification Broadband Imaging.

ACS Nano

December 2024

Nanophotonics Research Center, Institute of Microscale Optoelectronics and State Key Laboratory of Radio Frequency Heterogeneous, Shenzhen University, Shenzhen 518060, China.

Conventional microscopes, which rely on multiple objective lenses for varying magnifications, are bulky, complex, and costly, making them difficult to integrate into compact devices. They require frequent manual adjustments, complicating the imaging process and increasing maintenance burdens. This paper explores the potential of single ultrathin graphene metalens to address this issue.

View Article and Find Full Text PDF

Embedded CPU-GPU pupil tracking.

Biomed Opt Express

December 2024

Department of Ophthalmology, Stanford University, Palo Alto, CA 94303, USA.

We explore camera-based pupil tracking using high-level programming in computing platforms with end-user discrete and integrated central processing units (CPUs) and graphics processing units (GPUs), seeking low calculation latencies previously achieved with specialized hardware and programming (Kowalski et al., [Biomed. Opt.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!