Concentric ring electrodes have shown promise in non-invasive electrophysiological measurement demonstrating their superiority to conventional disc electrodes, in particular, in accuracy of Laplacian estimation. Recently, we have proposed novel variable inter-ring distances concentric ring electrodes. Analytic and finite element method modeling results for linearly increasing distances electrode configurations suggested they may decrease the truncation error resulting in more accurate Laplacian estimates compared to currently used constant inter-ring distances configurations. This study assesses statistical significance of Laplacian estimation accuracy improvement due to novel variable inter-ring distances concentric ring electrodes. Full factorial design of analysis of variance was used with one categorical and two numerical factors: the inter-ring distances, the electrode diameter, and the number of concentric rings in the electrode. The response variables were the Relative Error and the Maximum Error of Laplacian estimation computed using a finite element method model for each of the combinations of levels of three factors. Effects of the main factors and their interactions on Relative Error and Maximum Error were assessed and the obtained results suggest that all three factors have statistically significant effects in the model confirming the potential of using inter-ring distances as a means of improving accuracy of Laplacian estimation.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2017.8037760DOI Listing

Publication Analysis

Top Keywords

inter-ring distances
24
laplacian estimation
20
concentric ring
16
ring electrodes
16
novel variable
12
variable inter-ring
12
distances concentric
12
analysis variance
8
statistical significance
8
significance laplacian
8

Similar Publications

We report high-level calculations of the excited states of [2,2]-paracyclophane (PCP), which was recently investigated experimentally by ultrafast pump-probe experiments on oriented single crystals [Haggag et al., ChemPhotoChem 6 e202200181 (2022)]. PCP, in which the orientation of the two benzene rings and their range of motion are constrained, serves as a model for studying benzene excimer formation.

View Article and Find Full Text PDF
Article Synopsis
  • * Each mode in the fiber is well-separated from adjacent modes, ensuring stable transmission, which is crucial for effective communication performance.
  • * This fiber represents a promising option for spatial division multiplexing in optical communications, aimed at enhancing capacity for future high-speed systems, particularly over short distances.
View Article and Find Full Text PDF

Concentric ring electrodes are noninvasive and wearable sensors for electrophysiological measurement capable of estimating the surface Laplacian (second spatial derivative of surface potential) at each electrode. Significant progress has been made toward optimization of inter-ring distances (distances between the recording surfaces of the electrode), maximizing the accuracy of the surface Laplacian estimate based on the negligible dimensions model of the electrode. However, novel finite dimensions model offers comprehensive optimization including all of the electrode parameters simultaneously by including the radius of the central disc and the widths of the concentric rings into the model.

View Article and Find Full Text PDF

The optimization performed in this study is based on the finite dimensions model of the concentric ring electrode as opposed to the negligible dimensions model used in the past. This makes the optimization problem comprehensive, as all of the electrode parameters including, for the first time, the radius of the central disc and individual widths of concentric rings, are optimized simultaneously. The optimization criterion used is maximizing the accuracy of the surface Laplacian estimation, as the ability to estimate the Laplacian at each electrode constitutes primary biomedical significance of concentric ring electrodes.

View Article and Find Full Text PDF

Transition-metal sandwich complexes play key roles in various fields such as fundamental and applied chemistry; many of their unique properties arise from their ability to form stable or reactive ions. The first mass-analyzed threshold ionization (MATI) spectra of mixed sandwich compounds, (Ch)(Cp)Cr and (Cot)(Cp)Ti (Ch = η-CH, Cp = η-CH, Cot = η-CH), presented in this work provide an extremely accurate description of the electron detachment. The ionization energies of the neutrals and stabilization energies of the metal-ligand interactions upon ionization are derived from the MATI data with an accuracy of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!