Earlier studies have shown that short term heart rate variability (HRV) analysis of ECG seems promising for detection of epileptic seizures. A precise and accurate automatic R-peak detection algorithm is a necessity in a real-time, continuous measurement of HRV, in a portable ECG device. We used the portable CE marked ePatch® heart monitor to record the ECG of 14 patients, who were enrolled in the videoEEG long term monitoring unit for clinical workup of epilepsy. Recordings of the first 7 patients were used as training set of data for the R-peak detection algorithm and the recordings of the last 7 patients (467.6 recording hours) were used to test the performance of the algorithm. We aimed to modify an existing QRS-detection algorithm to a more precise R-peak detection algorithm to avoid the possible jitter Qand S-peaks can create in the tachogram, which causes error in short-term HRVanalysis. The proposed R-peak detection algorithm showed a high sensitivity (Se = 99.979%) and positive predictive value (P+ = 99.976%), which was comparable with a previously published QRS-detection algorithm for the ePatch® ECG device, when testing the same dataset. The novel R-peak detection algorithm designed to avoid jitter has very high sensitivity and specificity and thus is a suitable tool for a robust, fast, real-time HRV-analysis in patients with epilepsy, creating the possibility for real-time seizure detection for these patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC.2017.8037753 | DOI Listing |
Comput Biol Med
December 2024
Knight Foundation School of Computing and Information Sciences, Florida International University, 11200 SW 8th St CASE 352, Miami, 33199, FL, USA. Electronic address:
The electrocardiogram (ECG) is a vital device to examine the electrical activities of the heart. It is useful for diagnosing cardiovascular diseases, which often manifest themselves through alterations in the ECG signals' characteristics. These alterations are primarily observed in the signals' key components: the Q, R, S, T, and P peaks.
View Article and Find Full Text PDFRev Cardiovasc Med
October 2024
Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing, China.
Sleep Apnea (SA) is a prevalent sleep disorder with multifaceted etiologies that can have severe consequences for patients. Diagnosing SA traditionally relies on the in-laboratory polysomnogram (PSG), which records various human physiological activities overnight. SA diagnosis involves manual scoring by qualified physicians.
View Article and Find Full Text PDFPeerJ Comput Sci
September 2024
Department of Information and Communication Engineering, Myongji University, Yongin, Gyeonggi-do, Republic of South Korea.
Electrocardiograms (ECGs) provide essential data for diagnosing arrhythmias, which can potentially cause serious health complications. Early detection through continuous monitoring is crucial for timely intervention. The Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia dataset employed for arrhythmia analysis research comprises imbalanced data.
View Article and Find Full Text PDFSensors (Basel)
September 2024
School of Physical Education, Sport and Exercise Sciences, University of Otago, Dunedin 9054, New Zealand.
Low-cost, portable devices capable of accurate physiological measurements are attractive tools for coaches, athletes, and practitioners. The purpose of this study was primarily to establish the validity and reliability of Movesense HR+ ECG measurements compared to the criterion three-lead ECG, and secondarily, to test the industry leader Garmin HRM. Twenty-one healthy adults participated in running and cycling incremental test protocols to exhaustion, both with rest before and after.