A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reject option to reduce false prediction rates for EEG-motor imagery based BCI. | LitMetric

The Filter Bank Common Spatial Pattern (FBCSP) algorithm had been shown to be effective in performing multi-class Electroencephalogram (EEG) decoding of motor imagery using the one-versus-the-rest approach on the BCI Competition IV Dataset IIa. In this paper, we propose a method to reduce false detection rates of decoding through a rejection option based on the difference in the posterior probability computed by the Naïve Bayesian classifier. We applied the proposed approach on the BCI Competition IV Dataset IIa, and the results showed a decrease in the false detection rates from 34.6 % to 6.9%, while average decoded trials decreased from 93.2% to 34.2% using a rejection threshold between 0.1 and 0.9. We subsequently formulated a method to optimize the rejection threshold based on the maximum F score. The optimal rejection threshold yielded an average decrease in false detection rate to 19.1% with an average of 67.5% of trials decoded. The results showed the feasibility of decreasing false detection rates at a cost of rejection. Nevertheless, the results suggest that the use of reject option (RO) may be used as a training feedback system to train subjects' overt and covert EEG control strategies for better (dexterity and safety) continuous control of external device.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2017.8037479DOI Listing

Publication Analysis

Top Keywords

false detection
16
detection rates
12
rejection threshold
12
reject option
8
reduce false
8
approach bci
8
bci competition
8
competition dataset
8
dataset iia
8
decrease false
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!