A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel hardware implementation for detecting respiration rate using photoplethysmography. | LitMetric

Asthma is a serious public health problem. Continuous monitoring of breathing may offer an alternative way to assess disease status. In this paper we present a novel hardware implementation for the capture and storage of a photoplethysmography (PPG) signal. The LED duty cycle was altered to determine the effect on respiratory rate accuracy. The oximeter was mounted to the left index finger of ten healthy volunteers. The breathing rate derived from the oximeter was validated against a nasal airflow sensor. The duty cycle of a pulse oximeter was changed between 5%, 10% and 25% at a sample rate of 500 Hz. A PPG signal and reference signal was captured for each duty cycle. The PPG signals were post processed in Matlab to derive a respiration rate using an existing Matlab toolbox. At a 25% duty cycle the RMSE was <;2 breaths per minute for the top performing algorithm. The RMSE increased to over 5 breaths per minute when the duty cycle was reduced to 5%. The power consumed by the hardware for a 5%, 10% and 25% duty cycle was 5.4 mW, 7.8 mW, and 15 mW respectively. For clinical assessment of respiratory rate, a RSME of <;2 breaths per minute is recommended. Further work is required to determine utility in asthma management. However for non-clinical applications such as fitness tracking, lower accuracy may be sufficient to allow a reduced duty cycle setting.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2017.8036927DOI Listing

Publication Analysis

Top Keywords

duty cycle
16
novel hardware
8
hardware implementation
8
respiration rate
8
ppg signal
8
rate
5
implementation detecting
4
detecting respiration
4
rate photoplethysmography
4
photoplethysmography asthma
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!