This gamma scintigraphy imaging study was the first to assess pulmonary and extrathoracic deposition and regional lung deposition patterns of a radiolabelled long-acting muscarinic antagonist/long-acting β-agonist fixed-dose combination glycopyrronium/formoterol fumarate dihydrate (GFF) 14.4/10μg (equivalent to glycopyrrolate/formoterol fumarate 18/9.6μg), delivered by pressurized metered dose inhaler (pMDI) using novel co-suspension delivery technology. In this Phase I, randomized, single-centre, single-blind, single-dose, two-treatment, crossover, placebo-controlled study (PT003020), 10 healthy male adults received two actuations of GFF pMDI (7.2/5.0μg per actuation) and placebo pMDI (containing phospholipid-based porous particles without active pharmaceutical ingredient), both radiolabelled with Tc, up to 5MBq per actuation. Gamma scintigraphy images of lungs, stomach, head and neck were recorded. In addition, images of the actuators after use, collected mouth washings and exhalation filters were acquired. On average, 38.4% of the emitted dose of radiolabelled GFF pMDI, and 32.8% of radiolabelled placebo pMDI, was deposited in the lungs. The percentage emitted dose detected in the oropharyngeal and stomach regions was 61.4% and 66.9% for radiolabelled GFF pMDI and placebo pMDI, respectively. For both treatments, ≤0.25% of the emitted dose was detected in the exhalation filter. The normalized outer/inner ratio was 0.57 and 0.59 for radiolabelled GFF pMDI and placebo pMDI, respectively, and the standardized central/peripheral ratio was 1.85 and 1.94 respectively, indicating delivery of both co-suspension delivery technology formulations throughout the airways. There were no new or unexpected safety findings. In conclusion, both formulations were efficiently and uniformly deposited in the lungs with similar regional deposition patterns, oropharyngeal and stomach deposition, exhalation fraction and actuator-recovered dose.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejps.2017.10.026DOI Listing

Publication Analysis

Top Keywords

gff pmdi
16
placebo pmdi
16
co-suspension delivery
12
delivery technology
12
emitted dose
12
radiolabelled gff
12
pmdi
9
metered dose
8
dose inhaler
8
gamma scintigraphy
8

Similar Publications

This gamma scintigraphy imaging study was the first to assess pulmonary and extrathoracic deposition and regional lung deposition patterns of a radiolabelled long-acting muscarinic antagonist/long-acting β-agonist fixed-dose combination glycopyrronium/formoterol fumarate dihydrate (GFF) 14.4/10μg (equivalent to glycopyrrolate/formoterol fumarate 18/9.6μg), delivered by pressurized metered dose inhaler (pMDI) using novel co-suspension delivery technology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!