We present a method for calibration and data extraction for a nonoptimized Mueller matrix polarimeter. The advantage of this type of method is a reduction in measurement time for multiwavelength systems or in systems with slow response times. The calibration process requires the measurement of four known polarization devices. Here we use free-space transmission, a horizontal and a vertical linear polarizer, and a quarter-wave retarder with its fast axis at 30° to the horizontal. Experimental measurements of rotating quarter-wave and half-wave retarders show that accurate results can be obtained with the proposed method.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.56.004398DOI Listing

Publication Analysis

Top Keywords

calibration data
8
data extraction
8
extraction nonoptimized
8
nonoptimized mueller
8
mueller matrix
8
matrix polarimeters
4
polarimeters method
4
method calibration
4
matrix polarimeter
4
polarimeter advantage
4

Similar Publications

In-depth Computational Analysis Reveals The Significant Dysregulation of Key Gap Junction Proteins (GJPs) Driving Thoracic Aortic Aneurysm Development.

Hellenic J Cardiol

January 2025

Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA, 19096, USA; Department of Cardiac Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, PA, 19096, USA. Electronic address:

Objective: Thoracic Aortic Aneurysm (TAA) represents an aortic pathology that is caused by the deranged integrity of the three layers of the aortic wall, and is related to severe morbidity and mortality. Consequently, it is crucial to identify the biomarkers implicated in the pathogenesis and biology of TAA. The aim of the current computational study was to assess the differential gene expression profile of the gap junction proteins (GJPs) in patients with TAA in order to identify novel potential biomarkers for the diagnosis and treatment of this disease.

View Article and Find Full Text PDF

Integrated real-time intelligent control for wastewater treatment plants: Data-driven modeling for enhanced prediction and regulatory strategies.

Water Res

January 2025

State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin, 150090, China. Electronic address:

Both mechanical models and machine learning-based models are widely utilized for real-time dynamic control; however, their implementation in the water sector often incurs significant data and computational costs. To address these challenges, this study introduces an innovative feature extraction method designed to enhance the cost-effectiveness of dynamic control in wastewater treatment plants. The proposed method extracts dynamic features from time-series data of key substrate variables to construct a data-driven model and develop real-time control strategies.

View Article and Find Full Text PDF

ConvXGB: A novel deep learning model to predict recurrence risk of early-stage cervical cancer following surgery using multiparametric MRI images.

Transl Oncol

January 2025

State Key Laboratory of Oncogenes and Related Genes, Shanghai Cancer Institute, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China; Department of Radiology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Electronic address:

Background: Accurate estimation of recurrence risk for cervical cancer plays a pivot role in making individualized treatment plans. We aimed to develop and externally validate an end-to-end deep learning model for predicting recurrence risk in cervical cancer patients following surgery by using multiparametric MRI images.

Methods: The clinicopathologic data and multiparametric MRI images of 406 cervical cancer patients from three institutions were collected.

View Article and Find Full Text PDF

Atomic Force Microscopy (AFM) nanoindentation is the most effective method for determining the mechanical properties of soft biological materials and biomaterials at the nanoscale, with significant applications in many areas, including cancer diagnosis. However, a major drawback of this method is the complexity of the experimental procedure and data processing, which requires several calibration steps.To avoid this complexity, the AFM tip is usually approximated as a perfect cone.

View Article and Find Full Text PDF

Purpose: Heart failure (HF) is a disease that leads to approximately 300,000 fatalities annually in Europe and 250,000 deaths each year in the United States. Type 2 Diabetes Mellitus (T2DM) is a significant risk factor for HF, and testing for N-terminal (NT)-pro hormone BNP (NT-proBNP) can aid in early detection of HF in T2DM patients. We therefore developed and validated the HFriskT2DM-HScore, an algorithm to predict the risk of HF in T2DM patients, so guiding NT-proBNP investigation in a primary care setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!