A complete complex amplitude reconstruction method for the determination of the laser beam quality factor M based on the multiple exposure of a quadriwave lateral shearing interferometer (QWLSI) is presented. The theoretical analysis and simulation of the influence of the information in the small signal area on the calculation of the M factor is provided. The experimental results demonstrate that the new method can be an accurate means to measure the M factor. The proposed method can avoid the influence of phase inaccuracy in the small signal area of the interferogram, during the measurement of the M factor.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.56.007596 | DOI Listing |
Food Chem
December 2024
School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China. Electronic address:
Metal-organic frameworks (MOFs) are highly valued for their electronic and optical capabilities in food sample analysis. Implementing MOF-based sensors is crucial for public health safety. This review centers on electrochemiluminescence (ECL) MOFs for monitoring food samples, highlighting signal changes from combining MOFs with Ru(bpy), TPrA, nanomaterials, and biomolecules.
View Article and Find Full Text PDFTalanta
January 2025
Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China. Electronic address:
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has become a robust tool for analyzing a variety of biomacromolecules. However, the strong background interference produced by conventional organic matrices hinders the detection of small molecule analytes, which restricts the widespread application of MALDI-MS in metabolomics studies. Consequently, developing new organic matrices is urgently needed to overcome these issues.
View Article and Find Full Text PDFPhytomedicine
December 2024
Hebei Key Laboratory of Critical Disease Mechanism and Intervention, Department of Pathophysiology, Neuroscience Research Center, The Key Laboratory of Neural and Vascular Biology, Ministry of Education, Hebei Medical University, 361 Zhongshan East Road, Shijiazhuang 050017, China. Electronic address:
Background: In China, stroke is the primary cause of adult death and disability. Because of the increased rate of blood vessel reperfusion, it is important to prevent cerebral ischemia-reperfusion injury, in which glutamate (Glu) excitotoxicity plays a critical role. The most important Glu transporter, GLT-1, is essential for the regulation of Glu, which is dependent on Na-K-ATPase (NKA)-induced ion concentration gradient differences.
View Article and Find Full Text PDFJ Biomed Mater Res A
January 2025
Faculty of Materials Science and Engineering, Warsaw University of Technology, Warsaw, Poland.
Bone tissue regeneration can be affected by various architectonical features of 3D porous scaffold, for example, pore size and shape, strut size, curvature, or porosity. However, the design of additively manufactured structures studied so far was based on uniform geometrical figures and unit cell structures, which often do not resemble the natural architecture of cancellous bone. Therefore, the aim of this study was to investigate the effect of architectonical features of additively manufactured (aka 3D printed) titanium scaffolds designed based on microtomographic scans of fragments of human femurs of individuals of different ages on in vitro response of human bone-derived mesenchymal stem cells (hMSC).
View Article and Find Full Text PDFMass Spectrom (Tokyo)
December 2024
Department of Pharmaceutical Engineering, Faculty of Engineering, Toyama Prefectural University, 5180 Kurokawa, Imizu-City, Toyama 939-0398, Japan.
Matrix-assisted laser desorption/ionization (MALDI), surface-assisted laser desorption/ionization (SALDI), and time-of-flight mass spectrometry (TOFMS) imaging are used for visualizing the spatial distribution of analytes. Mass spectrometry (MS) imaging of a sample with a rough surface with a uniform distribution of an analyte does not provide uniform ion intensities in the image. A shift in the value of the analyte ions is also observed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!