Modern optical systems achieve incredible resolution and require more thorough testing. We present a method of evaluating and displaying the modulation transfer function (MTF) of a lens over its full rectangular field of view. The method consists of utilizing commercially available MTF test stations to gather data as well as custom software to plot the results. Critically, these measurements allow the characterization of misaligned systems with much higher accuracy than the typical three- or five-field-point MTF measurements yield. Examples are provided of both well-centered and poorly centered systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.56.005661 | DOI Listing |
J Ophthalmol
January 2025
Optics and Optometry Department, Universidad Complutense de Madrid, Madrid, Spain.
To analyze the refractive accuracy of a novel swept-source optical coherence biometer (SS-OCT), that uses individual refractive indices to measure axial length, in short and long eyes implanted with monofocal intraocular lenses (IOLs). This retrospective comparative study considered eyes with short axial length (AL) (< 22.5 mm) or long AL (> 26 mm) bilaterally implanted with the Acrysof IQ monofocal IOL.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
Sengi, Penniac, NB, Canada.
Purpose: To evaluate visual outcomes and quality of vision following bilateral implantation of a hydrophobic acrylic intraocular lens (IOL) in eyes targeted for emmetropia.
Methods: This was a prospective, single arm study. Subjects were bilaterally implanted with the Clareon PanOptix IOL and evaluated at 1 and 3 months postoperatively.
Zhonghua Yi Xue Za Zhi
January 2025
Ophthalmology Center, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou310009, China.
To develop and validate a predictive model for assessing the risk of early postoperative high intraocular pressure (HIOP) following posterior chamber intraocular lens implantation. The clinical data of patients who underwent posterior chamber intraocular lens implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine between May 2023 and April 2024 were retrospectively reviewed. Patients were divided into a modeling group and a validation group with a 7∶3 ratio using computerized random allocation.
View Article and Find Full Text PDFLife (Basel)
January 2025
Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, 61-553 Poznan, Poland.
To compare the accuracy of seven artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in medium-long Caucasian eyes regarding the root-mean-square absolute error (RMSAE), the median absolute error (MedAE) and the percentage of eyes with a prediction error (PE) within ±0.5 D. Data on Caucasian patients who underwent uneventful phacoemulsification between May 2018 and September 2023 in MW-Med Eye Center, Krakow, Poland and Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Kyiv, Ukraine were reviewed.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Department of Ophthalmology and Visual Sciences, McGill University, 5252 Maisonneuve Blvd W, 4th floor,, Montreal, Québec, H4A 3S5, Canada.
Objective: To assess refractive and visual outcomes of a spherical Implantable Collamer Lens (ICL) followed by planned postoperative adjunctive laser-assisted in situ keratomileusis (LASIK) in the treatment of high compound hyperopic astigmatism.
Methods: In this prospective, multi-center, multi-surgeon, single-arm trial, eyes with ≥ 3.50 D hyperopia and ≥ 2.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!