A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improved cumulative probabilities and range accuracy of a pulsed Geiger-mode avalanche photodiode laser ranging system with turbulence effects. | LitMetric

There exists a performance limitation in a pulsed Geiger-mode avalanche photodiode laser ranging system because of the echo intensity random fluctuation caused by turbulence effects. To suppress the influence of turbulence effects, we present a cumulative pulse detection technique with the ability to achieve improved cumulative probabilities and range accuracy. Based on the modulated Poisson model, the cumulative probabilities, range accuracy, and their influencing factors are investigated for a cumulative Q-switched laser pulse train. The results show that the improved cumulative probabilities and range accuracy can be obtained by utilizing cumulative pulse detection, with the condition that the echo intensity is 10, the echo pulse width is 10 ns, and the turbulence degree is 3, the target detection probability increases by 0.4, the false alarm probability decreases by 0.08, and the accuracy and precision increase by 46 cm and 27 cm, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.56.008216DOI Listing

Publication Analysis

Top Keywords

cumulative probabilities
16
probabilities range
16
range accuracy
16
improved cumulative
12
turbulence effects
12
pulsed geiger-mode
8
geiger-mode avalanche
8
avalanche photodiode
8
photodiode laser
8
laser ranging
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!