Introduction The aim of this study was to use variable life-adjusted display (VLAD) methodology to monitor performance of six vascular surgeons undertaking carotid endarterectomy in a single institution. Materials and methods This was a prospective study with continuous analysis. A risk score model to predict 30-day stroke or death for individual patients was developed from data collected from 839 patients from 1992 to 1999. The model was used to monitor performance of six surgeons from 2000 to 2009. Individual risk factors and 30-day outcomes were analysed and VLAD plots were created for the whole unit and for each surgeon. Results Among the 941 carotid endarterectomies in the performance analysis, 28 adverse events were recorded, giving an overall stroke or death rate of 3.06%. The risk model predicted there would be 33 adverse events. There was no statistical difference between the predicted and the observed adverse events (P > 0.2, χ2 value 1.25, 4 degrees of freedom). The VLAD plot for the whole unit shows an overall net gain in operative performance, although this could have been chance variation. The individual VLAD plot showed that surgeons 1, 2, 3 and 6 to have an overall net gain in the number of successful operations. The changes observed between the surgeons was not significant (P > 0.05) suggesting chance variation only. Conclusions Performance of carotid endarterectomy can be continuously assessed using VLAD methodology for units and individual surgeons. Early identification and correction of performance variation could facilitate improved quality of care.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5838674 | PMC |
http://dx.doi.org/10.1308/rcsann.2017.0170 | DOI Listing |
Matrix Biol
January 2025
Department of Surgery, Emory University, Atlanta, GA, USA; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA; Research Services, Atlanta VA Medical Center, Decatur, GA, USA. Electronic address:
Arterial endothelial cells (ECs) reside in a complex biomechanical environment. ECs sense and respond to wall shear stress. Low and oscillatory wall shear stress is characteristic of disturbed flow and commonly found at arterial bifurcations and around atherosclerotic plaques.
View Article and Find Full Text PDFJ Am Heart Assoc
January 2025
Department of Neurosurgery, Center of Pituitary Tumor, Ruijin Hospital Shanghai Jiao Tong University School of Medicine Shanghai China.
Background: Carotid endarterectomy (CEA) is widely used to treat carotid artery stenosis (CAS). However, the effects of CEA on unilateral CAS-induced cognitive impairment and the underlying mechanism remain poorly understood.
Methods And Results: Thirteen patients diagnosed with unilateral severe CAS underwent pre- and post-CEA assessments, including fluoro-2-deoxy-d-glucose positron emission tomography/magnetic resonance imaging, cognitive assessments, and routine blood tests before and after CEA.
Cureus
December 2024
Department of Cardiology, Geetanjali Medical College and Hospital, Udaipur, IND.
Background Carotid artery stenting is a well-established alternative treatment to carotid endarterectomy for carotid artery stenosis for preventing stroke. This study assessed the procedural and clinical outcomes in patients undergoing carotid artery stenting in a tertiary care center in India. Methods A total of 39 patients underwent carotid artery stenting from January 2022 to December 2023, with different embolic protection devices and carotid stents.
View Article and Find Full Text PDFAnn Ital Chir
January 2025
Institute of Central Nervous System Vascular Injury and Repair, Jining Medical Science Research Institute, The First People's Hospital of Jining, 272000 Jining, Shandong, China.
Aim: This study aims to report a rare case of an embolization protection device (EPD) entrapment during Carotid Artery Stent (CAS) and to discuss the management strategy, including open surgery and concurrent carotid endarterectomy (CEA).
Case Presentation: A 71-year-old female presented with left limb weakness and unclear speech following CAS. Imaging revealed a new cerebral infarction and right internal carotid artery stenosis.
JACC Cardiovasc Interv
December 2024
Department for Angiology, Brandenburg Medical School Theodor Fontane, Campus Clinic Brandenburg, Center for Internal Medicine I, Berlin, Germany; Department of Angiology, Sankt-Gertrauden-Krankenhaus, Berlin, Germany.
Background: Several randomized clinical trials have shown that the composite endpoint of death, stroke, and myocardial infarction (MI) is equivalent between carotid artery stenting and carotid endarterectomy. However, the risk of minor stroke has been consistently higher with carotid artery stenting.
Objectives: The authors sought to evaluate the safety and effectiveness of a novel carotid stent system comprised of a stent, an adjustable integrated embolic filter and a postdilation balloon, in patients at elevated risk for adverse events from carotid endarterectomy.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!