A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High total volatile organic compounds pollution in a hospital dental department. | LitMetric

High total volatile organic compounds pollution in a hospital dental department.

Environ Monit Assess

Department of Respiratory Therapy, College of Medicine, Chang Gung University, Taoyuan, Taiwan, Republic of China.

Published: October 2017

Bioaerosols produced by dental procedures may affect indoor air quality and cause infections in dental healthcare workers. To provide air quality data that can be used to protect dental healthcare workers, this study evaluated the air quality and its influencing factors in the dental department of the Chang Gung Memorial Hospital in Taiwan. The study was a cross-sectional study design. Indoor air quality (IAQ) evaluations were conducted in six locations: pediatric dentistry, craniofacial orthodontic dentistry, periodontal dentistry, and general practice dentistry, instrument washing room, and patient waiting area. The measured air quality parameters included temperature, relative humidity, and concentrations of CO, total volatile organic compounds (TVOCs), suspended particulate matter (PM), and bacteria. TVOCs concentrations at all six sampling stations were found to exceed the indoor air quality standards prescribed by the Taiwan Environmental Protection Agency. The highest concentrations of atmospheric PM, PM, and PM were found in the periodontal dentistry department, while the lowest concentrations occurred in the patient waiting area. The detection rate for Gram-positive bacteria was highest in the pediatric department (25%) and lowest in the instrument washing room (9%). Micrococcus luteus and Bacillus cereus were the primary pathogens detected. The dental departments of the hospital had a serious TVOCs pollution. The air quality of dental departments deserves long-term surveillance and attention.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5691115PMC
http://dx.doi.org/10.1007/s10661-017-6265-zDOI Listing

Publication Analysis

Top Keywords

air quality
28
indoor air
12
total volatile
8
volatile organic
8
organic compounds
8
dental department
8
dental healthcare
8
healthcare workers
8
periodontal dentistry
8
instrument washing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!