We introduce the concept of a miniaturized compound refractive X-ray zoom lens consisting of SU-8 lenses fabricated by deep X-ray lithography. The focal length can be varied by changing the number of lens elements placed in the beam. We use suitable actuators to move single lens elements reversibly out of the beam. The X-ray zoom lens can accept different X-ray energies while keeping a fixed working distance, or vary the focal distance for a fixed energy. The latter is useful in tuning the magnification factor in full field microscopy.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.25.022455DOI Listing

Publication Analysis

Top Keywords

x-ray zoom
12
zoom lens
12
miniaturized compound
8
compound refractive
8
refractive x-ray
8
lens elements
8
x-ray
5
lens
5
lens introduce
4
introduce concept
4

Similar Publications

Article Synopsis
  • Alzheimer's disease (AD) is a serious neurological condition affecting millions, making early and accurate diagnosis crucial for better management and patient outcomes.* -
  • This study presents ViTAD, a new method using a modified Vision Transformer model to classify five stages of AD from brain MRI images, achieving a remarkable 99.98% accuracy.* -
  • ViTAD outperforms traditional CNN models in both speed and accuracy, demonstrating its potential as a valuable tool for early diagnosis of Alzheimer's in clinical settings.*
View Article and Find Full Text PDF

Background: Aspiration thrombectomy is one of the mainstays for stroke interventions. The Zoom 71 (Z71) aspiration catheter is unique with its angled tip. This study describes the orientation of the angled tip as it is navigated around the carotid siphon in relation to trackability.

View Article and Find Full Text PDF
Article Synopsis
  • Zebrafish serve as a key model for studying neurodegenerative diseases, but achieving cellular resolution in their brain imaging has been difficult.
  • The study presents groundbreaking MRI results at a high magnetic field strength of 28.2 T, achieving a 20% better signal-to-noise ratio compared to the previous 17.6 T, allowing for clearer brain structure visualization.
  • Advanced imaging techniques like diffusion tensor imaging (DTI) and constrained spherical deconvolution are used to non-invasively identify white matter structures with high resolution, paving the way for better understanding of microstructural changes in zebrafish models of brain diseases.
View Article and Find Full Text PDF

Purpose: Multi-zoom microscopic surface reconstructions of operating sites, especially in ENT surgeries, would allow multimodal image fusion for determining the amount of resected tissue, for recognizing critical structures, and novel tools for intraoperative quality assurance. State-of-the-art three-dimensional model creation of the surgical scene is challenged by the surgical environment, illumination, and the homogeneous structures of skin, muscle, bones, etc., that lack invariant features for stereo reconstruction.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to create a CT-based deep learning model for distinguishing low-risk and high-risk thymoma, comparing its performance with that of radiologists.
  • - A total of 159 patients were analyzed using a fine-tuned VGG16 model with various data augmentations, resulting in a DL accuracy of 71.3%.
  • - While the DL model improved diagnostic accuracy for radiologists, the overall performance, gauged by the area under the curve (AUC), showed no significant differences with or without the model.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!