Evaluation of the use of the fourth version FloTrac system in cardiac output measurement before and after cardiopulmonary bypass.

J Clin Monit Comput

Department of Anesthesiology, Chang Gung Memorial Hospital, Linkou Medical Center, No.5, Fuxing St., Guishan Dist., Taoyuan, 333, Taiwan.

Published: October 2018

The FloTrac system is a system for cardiac output (CO) measurement that is less invasive than the pulmonary artery catheter (PAC). The purposes of this study were to (1) compare the level of agreement and trending abilities of CO values measured using the fourth version of the FloTrac system (CCO-FloTrac) and PAC-originated continuous thermodilution (CCO-PAC) and (2) analyze the inadequate CO-discriminating ability of the FloTrac system before and after cardiopulmonary bypass (CPB). Fifty patients were included. After exclusion, 32 patients undergoing cardiac surgery with CPB were analyzed. All patients were monitored with a PAC and radial artery catheter connected to the FloTrac system. CO was assessed at 10 timing points during the surgery. In the Bland-Altman analysis, the percentage errors (bias, the limits of agreement) of the CCO-FloTrac were 61.82% (0.16, - 2.15 to 2.47 L min) and 51.80% (0.48, - 1.97 to 2.94 L min) before and after CPB, respectively, compared with CCO-PAC. The concordance rates in the four-quadrant plot were 64.10 and 62.16% and the angular concordance rates (angular mean bias, the radial limits of agreement) in the polar-plot analysis were 30.00% (17.62°, - 70.69° to 105.93°) and 38.63% (- 10.04°, - 96.73° to 76.30°) before and after CPB, respectively. The area under the receiver operating characteristic curve for CCO-FloTrac was 0.56, 0.52, 0.52, and 0.72 for all, ≥ ± 5, ≥ ± 10, and ≥ ± 15% CO changes (ΔCO) of CCO-PAC before CPB, respectively, and 0.59, 0.55, 0.49, and 0.46 for all, ≥ ± 5, ≥ ± 10, and ≥ ± 15% ΔCO of CCO-PAC after CPB, respectively. When CO < 4 L/min was considered inadequate, the Cohen κ coefficient was 0.355 and 0.373 before and after CPB, respectively. The accuracy, trending ability, and inadequate CO-discriminating ability of the fourth version of the FloTrac system in CO monitoring are not statistically acceptable in cardiac surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10877-017-0071-6DOI Listing

Publication Analysis

Top Keywords

flotrac system
20
fourth version
8
version flotrac
8
system cardiac
8
cardiac output
8
output measurement
8
cardiopulmonary bypass
8
artery catheter
8
limits agreement
8
concordance rates
8

Similar Publications

Introduction: Dynamic indices of fluid responsiveness (FR) such as pulse pressure variation (PPV) and stroke volume variation (SVV) differ among hemodynamic monitors, which use proprietary algorithms, and vary even over a short period of time. We aimed to compare the baseline values, fluctuation and predictive value for FR of PPV and SVV measured by three minimally invasive monitors.

Patients And Methods: Twenty patients undergoing high-risk abdominal surgery were included and 45 fluid challenges were analysed.

View Article and Find Full Text PDF

Background: Hypotension during dialysis arises from vasomotor tone alterations and hypovolemia, with disrupted counterregulatory mechanisms in acute kidney injury (AKI) patients. This study investigated the predictive value of preload dependency, assessed by the passive leg raising (PLR) test, and arterial tone, measured by dynamic elastance (Eadyn), for intradialytic hypotension (IDH).

Methods: In this prospective observational study conducted in a tertiary hospital ICU, hemodynamic parameters were collected from critically ill AKI patients undergoing intermittent hemodialysis using the FloTrac/Vigileo system.

View Article and Find Full Text PDF

Background: When applying lung-protective ventilation, fluid responsiveness cannot be predicted by pulse pressure variation (PPV) or stroke volume variation (SVV). Functional hemodynamic testing may help address this limitation. This study examined whether changes in dynamic indices such as PPV and SVV, induced by tidal volume challenge (TVC), can reliably predict fluid responsiveness in patients undergoing renal transplantation who receive lung-protective ventilation.

View Article and Find Full Text PDF

Intraoperative hypotension (IH) is common in patients receiving general anesthesia and can lead to serious complications such as kidney failure, myocardial injury and increased mortality. The Hypotension Prediction Index (HPI) algorithm is a machine learning system that analyzes the arterial pressure waveform and alerts the clinician of an impending hypotension event. The purpose of the study was to compare the frequency of perioperative hypotension in patients undergoing major abdominal surgery with different types of hemodynamic monitoring.

View Article and Find Full Text PDF

Naphazoline intoxication managed with minimally invasive cardiac output monitoring.

Am J Emerg Med

March 2024

Department of Emergency and Critical Care Medicine, Saitama Medical Center, Jichi Medical University, Saitama, Japan. Electronic address:

Article Synopsis
  • * The patient showed severe symptoms related to naphazoline intoxication, including bradycardia and high blood pressure, prompting treatment with phentolamine and nicardipine under careful monitoring of systemic vascular resistance.
  • * Successful treatment led to normalization of vascular resistance and the patient was discharged after four days, indicating the effectiveness of using advanced monitoring systems to manage such cases.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!