Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Femtosecond transient absorption was used to study excitation decay in monomeric and trimeric cyanobacterial Photosystem I (PSI) being prepared in three states: (1) in aqueous solution, (2) deposited and dried on glass surface (either conducting or non-conducting), and (3) deposited on glass (conducting) surface but being in contact with aqueous solvent. The main goal of this contribution was to determine the reason of the acceleration of the excitation decay in dried PSI deposited on the conducting surface relative to PSI in solution observed previously using time-resolved fluorescence (Szewczyk et al., Photysnth Res 132(2):111-126, 2017). We formulated two alternative working hypotheses: (1) the acceleration results from electron injection from PSI to the conducting surface; (2) the acceleration is caused by dehydration and/or crowding of PSI proteins deposited on the glass substrate. Excitation dynamics of PSI in all three types of samples can be described by three main components of subpicosecond, 3-5, and 20-26 ps lifetimes of different relative contributions in solution than in PSI-substrate systems. The presence of similar kinetic components for all the samples indicates intactness of PSI proteins after their deposition onto the substrates. The kinetic traces for all systems with PSI deposited on substrates are almost identical and they decay significantly faster than the kinetic traces of PSI in solution. We conclude that the accelerated excitation decay in PSI-substrate systems is caused mostly by dense packing of proteins.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5895687 | PMC |
http://dx.doi.org/10.1007/s11120-017-0454-z | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!