Background: Acute aortic syndromes (AASs) are rare and severe cardiovascular emergencies with unspecific symptoms. For AASs, both misdiagnosis and overtesting are key concerns, and standardized diagnostic strategies may help physicians to balance these risks. D-dimer (DD) is highly sensitive for AAS but is inadequate as a stand-alone test. Integration of pretest probability assessment with DD testing is feasible, but the safety and efficiency of such a diagnostic strategy are currently unknown.

Methods: In a multicenter prospective observational study involving 6 hospitals in 4 countries from 2014 to 2016, consecutive outpatients were eligible if they had ≥1 of the following: chest/abdominal/back pain, syncope, perfusion deficit, and if AAS was in the differential diagnosis. The tool for pretest probability assessment was the aortic dissection detection risk score (ADD-RS, 0-3) per current guidelines. DD was considered negative (DD-) if <500 ng/mL. Final case adjudication was based on conclusive diagnostic imaging, autopsy, surgery, or 14-day follow-up. Outcomes were the failure rate and efficiency of a diagnostic strategy for ruling out AAS in patients with ADD-RS=0/DD- or ADD-RS ≤1/DD-.

Results: A total of 1850 patients were analyzed. Of these, 438 patients (24%) had ADD-RS=0, 1071 patients (58%) had ADD-RS=1, and 341 patients (18%) had ADD-RS >1. Two hundred forty-one patients (13%) had AAS: 125 had type A aortic dissection, 53 had type B aortic dissection, 35 had intramural aortic hematoma, 18 had aortic rupture, and 10 had penetrating aortic ulcer. A positive DD test result had an overall sensitivity of 96.7% (95% confidence interval [CI], 93.6-98.6) and a specificity of 64% (95% CI, 61.6-66.4) for the diagnosis of AAS; 8 patients with AAS had DD-. In 294 patients with ADD-RS=0/DD-, 1 case of AAS was observed. This yielded a failure rate of 0.3% (95% CI, 0.1-1.9) and an efficiency of 15.9% (95% CI, 14.3-17.6) for the ADD-RS=0/DD- strategy. In 924 patients with ADD-RS ≤1/DD-, 3 cases of AAS were observed. This yielded a failure rate of 0.3% (95% CI, 0.1-1) and an efficiency of 49.9% (95% CI, 47.7-52.2) for the ADD-RS ≤1/DD- strategy.

Conclusions: Integration of ADD-RS (either ADD-RS=0 or ADD-RS ≤1) with DD may be considered to standardize diagnostic rule out of AAS.

Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02086136.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.117.029457DOI Listing

Publication Analysis

Top Keywords

aortic dissection
16
aortic
9
dissection detection
8
detection risk
8
risk score
8
acute aortic
8
aortic syndromes
8
pretest probability
8
probability assessment
8
type aortic
8

Similar Publications

Background: Acute aortic dissection is a lethal cardiovascular emergency; early diagnosis is critically necessary. Novel serum biomarkers can potentially help in early detection and estimation of postoperative outcomes. Yes-associated protein (YAP) is a critical effector of the Hippo pathway, our aim was to explore the association between YAP and the diagnosis and prognosis of AD.

View Article and Find Full Text PDF

Four-dimensional flow magnetic resonance imaging (4D flow MRI) was utilized to analyze an aortic dissection with an aberrant right subclavian artery, revealing vortex formation and an increased oscillatory shear index (OSI), both indicative of variations in wall shear stress. An elevated OSI has been associated with an elevated risk of aortic dissection.

View Article and Find Full Text PDF

Patients with pregnancy-related aortic dissections should be transferred to high-volume aortic centers for management. Malperfusion syndromes from acute type A aortic dissections appear to have better outcomes with thoracic endovascular repair before definitive surgical repair.

View Article and Find Full Text PDF

Chest computed tomography (CT) is essential for diagnosing and monitoring thoracic aortic dilations and aneurysms, conditions that place patients at risk of complications such as aortic dissection and rupture. However, aortic measurements in chest CT radiology reports are often embedded in free-text formats, limiting their accessibility for clinical care, quality improvement and research purposes. In this study, we developed a multi-method pipeline to extract structured aortic measurements from radiology reports, and compared the performance of fine-tuned BERT-based models with instruction-tuned Llama large language models (LLMs).

View Article and Find Full Text PDF

Early clinical outcomes of transcatheter aortic valve implantation using the NAVITOR system.

Cardiovasc Interv Ther

January 2025

Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan.

Transcatheter aortic valve implantation (TAVI) using the NAVITOR system has been relatively underreported due to its recent introduction in Japan. This study aimed to assess the short-term outcomes of TAVI with the NAVITOR in real-world clinical practice. Patients with severe aortic stenosis who underwent TAVI using the NAVITOR system at our institution between December 2022 and December 2023 were prospectively enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!