A Method to Quantitatively Assess Dermal Exposure to Volatile Organic Compounds.

Ann Work Expo Health

Centre for Environment and Health, Department of Public Health and Primary Care, KU Leuven, Kapucijnenvoer 35 - 6th floor box 7001, 3000 , Leuven, Belgium, Belgium.

Published: October 2017

AI Article Synopsis

  • Assessing the skin exposure of workers to harmful chemicals, particularly volatile organic compounds (VOCs), is crucial in industrial environments, but existing methods lack accuracy for quantification.
  • A new methodology using activated charcoal cloth (ACC) was developed, proving effective in quantitatively measuring skin exposure to 181 different VOCs, with most showing nearly 100% desorption efficiency over a range of concentrations.
  • The study demonstrated that ACC is a reliable and sensitive sampling material for evaluating dermal exposure, paving the way for more detailed research and improved occupational safety assessments regarding skin exposure to VOCs.

Article Abstract

Assessing dermal exposure of workers to noxious chemicals becomes increasingly important in industrial settings. Among various chemicals, volatile organic compounds (VOCs) are widely used in industrialized countries, but still there are no validated methodologies able to accurately quantify skin exposure. In this study, we developed a sensitive methodology based on activated charcoal cloth (ACC) to quantitatively assess skin exposure to 181 VOCs. The majority of the VOCs (156) showed a constant desorption efficiency (DE) of ~100% over the studied concentration range. Seven VOCs showed a concentration dependency for the DEs, which we described by a Dubinin-Raduskevich desorption isotherm. For 18 compounds, the DEs were situated below 80% but showed to be constant over the concentration range. All tested VOCs showed a good storage stability on ACC, especially at -80°C storage. Only for n-pentane there was a decrease of ~40% when it was stored for a month. In a controlled environment test, ACC has shown to reflect well the increasing concentrations of VOCs in the air with a high linearity (R2 ≥ 0.812, except for gamma-butyrolactone where R2 = 0.570). In this study, we show that ACC is a suitable sampling material for quantitatively assessing dermal exposure to 181 VOCs in terms of sensitivity and DE. This method will allow more studies that are detailed on dermal exposure, which will lead to a better assessment of skin exposure in occupational settings.

Download full-text PDF

Source
http://dx.doi.org/10.1093/annweh/wxx054DOI Listing

Publication Analysis

Top Keywords

dermal exposure
16
skin exposure
12
quantitatively assess
8
volatile organic
8
organic compounds
8
assessing dermal
8
exposure 181
8
181 vocs
8
concentration range
8
exposure
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!