A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quartz crystal microbalance as an assay to detect anti-drug antibodies for the immunogenicity assessment of therapeutic biologics. | LitMetric

Quartz crystal microbalance as an assay to detect anti-drug antibodies for the immunogenicity assessment of therapeutic biologics.

Anal Bioanal Chem

Laboratoire de bio-ingénierie et de biophysique de l'Université de Sherbrooke, Department of Chemical and Biotechnological Engineering, Université de Sherbrooke, 2500 boulevard de l'Université, Sherbrooke, Québec, J1K 2R1, Canada.

Published: December 2017

Because of their biological origins, therapeutic biologics can trigger an unwanted deleterious immune response with some patients. The immunogenicity of therapeutic biologics can affect drug efficacy and patient safety by the production of circulating anti-drug antibodies (ADA). In this study, quartz crystal microbalance (QCM) was developed as an assay to detect ADA. Etanercept (Enbrel®) was covalently grafted to dextran-modified QCM surfaces. Rabbits were immunized with etanercept to generate ADA. Results showed the QCM assay could detect purified ADA from rabbits at concentrations as low as 50 ng/mL, within the sensitivity range of ELISA. The QCM assay could also assess the ADA isotype. It was shown that the ADA were composed of the IgG isotype, but not IgM, as expected. Furthermore, it was shown that QCM surfaces that had been used to detect ADA could be regenerated in glycine-HCl solution and reused. The QCM assay was also demonstrated to detect ADA in crude serum samples. Serum was collected from the rabbits and analyzed before and after etanercept immunization. ADA were clearly detected in serum from rabbits after immunization, but not in serum before immunization. Serum from patients administered with etanercept for rheumatoid arthritis (RA) treatment was also analyzed and compared to serum from healthy donors. Sera from 10 RA patients were analyzed. Results showed one of the RA patient serum samples may have ADA present. In conclusion, QCM appears to be a viable assay to detect ADA for the immunogenicity assessment of therapeutic biologics.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-017-0674-2DOI Listing

Publication Analysis

Top Keywords

assay detect
16
therapeutic biologics
16
detect ada
16
qcm assay
12
ada
11
quartz crystal
8
crystal microbalance
8
anti-drug antibodies
8
immunogenicity assessment
8
assessment therapeutic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!