Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Posthepatectomy liver failure (PHLF) is one of the most serious complications after hepatectomy. The objective of the present study is to assess the potential diagnostic ability of Tc-galactosyl human serum albumin (GSA) scintigraphy to predict PHLF as defined by the International Study Group of Liver Surgery (ISGLS).
Materials And Methods: Data from 100 patients who underwent Tc-GSA scintigraphy and subsequent hepatectomy were retrospectively analyzed. The blood clearance ratio (HH15), hepatic uptake ratio (LHL15), and maximal removal rate (Rmax) of Tc-GSA (GSA-Rmax) were calculated as scintigraphic parameters for the total liver. In addition to the ratio of preoperatively estimated remnant liver (ERL) counts to total liver counts (rERL-GSA), the ratio of actual remnant liver (ARL) counts to total liver counts (rARL-GSA), determined by applying a more accurate resection line with reference to both pre- and postoperative CT, was obtained from SPECT images. Functional remnant liver parameters of ERL-LHL15 (LHL15 of the estimated remnant liver), ERL-Rmax (maximal removal rate of estimated remnant liver counts), ARL-LHL15 (LHL15 of the actual remnant liver), and ARL-Rmax (maximal removal rate of actual remnant liver counts) were calculated using these values. ROC analysis was performed to evaluate the ability of these parameters to predict PHLF. Multivariate analysis was performed to identify independent predictors of PHLF.
Results: PHLF occurred in 33 patients. Each of the ARL parameters had a significantly higher diagnostic performance compared with the corresponding ERL parameter (AUC values: for rARL-GSA vs rERL-GSA, 0.77 vs 0.62 [p = 0.0004]; for ARL-LHL15 vs ERL-LHL15, 0.79 vs 0.64 [p = 0.0005]; and for ARL-Rmax vs ERL-Rmax, 0.78 vs 0.66 [p = 0.0003]). According to multivariate analysis, each of three ARL parameters was identified as an independent predictor of PHLF (p < 0.0001 for all).
Conclusion: Technetium-99m-labeled GSA scintigraphy is useful for predicting PHLF, particularly for applying an accurate resection line on GSA-SPECT images.