A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Predictability of Tc-Galactosyl Human Serum Albumin Scintigraphy for Posthepatectomy Liver Failure. | LitMetric

Predictability of Tc-Galactosyl Human Serum Albumin Scintigraphy for Posthepatectomy Liver Failure.

AJR Am J Roentgenol

1 Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoinkawahara-cho, Sakyo-Ku, Kyoto, 606-8507, Japan.

Published: January 2018

Objective: Posthepatectomy liver failure (PHLF) is one of the most serious complications after hepatectomy. The objective of the present study is to assess the potential diagnostic ability of Tc-galactosyl human serum albumin (GSA) scintigraphy to predict PHLF as defined by the International Study Group of Liver Surgery (ISGLS).

Materials And Methods: Data from 100 patients who underwent Tc-GSA scintigraphy and subsequent hepatectomy were retrospectively analyzed. The blood clearance ratio (HH15), hepatic uptake ratio (LHL15), and maximal removal rate (Rmax) of Tc-GSA (GSA-Rmax) were calculated as scintigraphic parameters for the total liver. In addition to the ratio of preoperatively estimated remnant liver (ERL) counts to total liver counts (rERL-GSA), the ratio of actual remnant liver (ARL) counts to total liver counts (rARL-GSA), determined by applying a more accurate resection line with reference to both pre- and postoperative CT, was obtained from SPECT images. Functional remnant liver parameters of ERL-LHL15 (LHL15 of the estimated remnant liver), ERL-Rmax (maximal removal rate of estimated remnant liver counts), ARL-LHL15 (LHL15 of the actual remnant liver), and ARL-Rmax (maximal removal rate of actual remnant liver counts) were calculated using these values. ROC analysis was performed to evaluate the ability of these parameters to predict PHLF. Multivariate analysis was performed to identify independent predictors of PHLF.

Results: PHLF occurred in 33 patients. Each of the ARL parameters had a significantly higher diagnostic performance compared with the corresponding ERL parameter (AUC values: for rARL-GSA vs rERL-GSA, 0.77 vs 0.62 [p = 0.0004]; for ARL-LHL15 vs ERL-LHL15, 0.79 vs 0.64 [p = 0.0005]; and for ARL-Rmax vs ERL-Rmax, 0.78 vs 0.66 [p = 0.0003]). According to multivariate analysis, each of three ARL parameters was identified as an independent predictor of PHLF (p < 0.0001 for all).

Conclusion: Technetium-99m-labeled GSA scintigraphy is useful for predicting PHLF, particularly for applying an accurate resection line on GSA-SPECT images.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.17.18411DOI Listing

Publication Analysis

Top Keywords

remnant liver
28
liver counts
16
liver
13
maximal removal
12
removal rate
12
total liver
12
estimated remnant
12
actual remnant
12
tc-galactosyl human
8
human serum
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!