Background: This study evaluated the clinical and radiographic outcomes of a series of patients treated with an anatomic inlay resurfacing implant, with a minimum two-year follow-up.

Methods: Fifteen patients underwent patellofemoral-resurfacing procedures using a HemiCAP Wave Patellofemoral Inlay Resurfacing implant from 2010 to 2013. Clinical outcomes included: Visual Analog Scale (VAS), Lysholm score, Knee Society Score (KSS), and evaluation of Kujala, and Hospital for Special Surgery Patellofemoral score (HSS-PF). The postoperative complications were analyzed.

Results: Nineteen knees were evaluated; the average follow-up was 35.2months. Fourteen were women, with an average age of 54years. The pre-operative/postoperative clinical results presented a significant improvement: VAS 8/2.5, Lysholm 31.9/85.8, KSS 39.8/82.5, Kujala 32.1/79.3 and Hospital for Special Surgery Patellofemoral score (HSS-PF) 15.9/90.6. A total of 87% of patients were either satisfied or very satisfied with the overall outcome. There were no radiographic signs of loosening. Seven postoperative complications were recorded: two presented ongoing knee pain, one postoperative stiffness, one patellar bounce due to maltracking, two ilio-tibial band syndrome, and one tibial anterior tuberosity osteotomy nonunion. Two patients underwent a total knee arthroplasty conversion and were considered a failure. None of these complications were implant related.

Conclusions: Patellofemoral inlay resurfacing for isolated patellofemoral arthritis was an effective and safe procedure with high levels of patient satisfaction. No mechanical implant failure was seen at a minimum two-year follow-up. This implant design appeared to be an alternative to the traditional patellofemoral prostheses. Concomitant osteochondral lesions, patellofemoral dysplasia or patellar maltracking might be poor prognostic factors for this type of implant.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.knee.2017.09.003DOI Listing

Publication Analysis

Top Keywords

resurfacing implant
12
minimum two-year
12
inlay resurfacing
12
patellofemoral
8
patellofemoral arthritis
8
two-year follow-up
8
patients underwent
8
patellofemoral inlay
8
hospital special
8
special surgery
8

Similar Publications

Safe tibial subsidence pattern of a medial pivot knee. An RSA study.

J Orthop

July 2025

Fremantle Hospital, Orthopaedics Research Foundation of WA Alma St, 6160, Fremantle, WA, Australia.

Introduction: Micromotion analysis predicts component fixation survival in Total Knee Arthroplasty (TKA) but a paucity of literature exists for medial pivot designs. This clinical study examined the tibial component micromotion in a second-generation medial pivot TKA.

Methods: This prospective single-center clinical cohort trial involved 35 patients with a mean patient age of 71 years.

View Article and Find Full Text PDF

The potential carcinogenicity of orthopaedic implants - a scoping review.

BMC Cancer

December 2024

Department of Orthopaedics and Traumatology, School of Clinical Medicine, Faculty of Medicine, The University of Hong Kong, Hong Kong, China.

Background: Every year, hundreds of thousands of patients receive an orthopaedic or dental implant containing metals such as cobalt, chromium and titanium. Since the European Chemicals Agency (2020) classified pure cobalt metal as a Category 1B carcinogen, manufacturers of products containing ≥ 0.1% of this metal must perform a risk assessment and justify that there are no viable alternatives.

View Article and Find Full Text PDF

Purpose: Hip resurfacing arthroplasty (HRA) is recommended for younger patients seeking higher levels of activity. However, femoroacetabular cup impingement (FACI) between the femoral neck and acetabular prosthesis remains a concern. This study aimed to determine the incidence, risk factors, and prognostic consequences of FACI after HRA.

View Article and Find Full Text PDF

Biomechanical Evaluation of a Femoral Implant for Hip Resurfacing Arthroplasty in Dogs: An Ex Vivo Study.

Vet Comp Orthop Traumatol

December 2024

Department of Clinic and Veterinary Surgery, School of Agricultural and Veterinarian Sciences, São Paulo State University (UNESP), Jaboticabal, Sao Paulo, Brazil.

Article Synopsis
  • - The study aimed to evaluate how stable a hip resurfacing prosthesis is in dog cadaver femurs using various biomechanical tests.
  • - Twenty canine femurs were tested, with one femur receiving the prosthesis and the other remaining intact; the tests measured load capacity and displacement during stress.
  • - Results showed that the prosthesis had lower maximum load and load at collapse values compared to intact femurs, but similar behavior in terms of displacement and stiffness, indicating some limitations in the prosthesis's performance.
View Article and Find Full Text PDF

Background: Symptomatic cartilage defects of the knee joint are frequently diagnosed and can be treated with different available surgical methods. Nevertheless, there is currently no gold standard treatment for all indications. Minced cartilage implantation is increasingly coming into focus as a refined surgical technique.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!