Fluctuation Scaling, Calibration of Dispersion, and Detection of Differences.

Anal Chem

School of Science and Technology, Nottingham Trent University, Clifton Lane, Nottingham NG11 8NS, United Kingdom.

Published: November 2017

Fluctuation scaling describes the relationship between the mean and standard deviation of a set of measurements. An example is Horwitz scaling, which has been reported from interlaboratory studies. Horwitz and similar studies have reported simple exponential and segmented scaling laws with exponents (α) typically between 0.85 (Horwitz) and 1 when not operating near a detection limit. When approaching a detection limit, the exponents change and approach an apparently Gaussian (α = 0) model. This behavior is often presented as a property of interlaboratory studies, which makes controlled replication to understand the behavior costly to perform. To assess the contribution of instrumentation to larger scale fluctuation scaling, we measured the behavior of two inductively coupled plasma atomic emission spectrometry (ICP-AES) systems, in two laboratories measuring thulium using two emission lines. The standard deviation universally increased with the uncalibrated signal, indicating the system was heteroscedastic. The response from all lines and both instruments was consistent with a single exponential dispersion model having parameters α = 1.09 and β = 0.0035. No evidence of Horwitz scaling was found, and there was no evidence of Poisson noise limiting behavior. The "Gaussian" component was a consequence of background subtraction for all lines and both instruments. The observation of a simple exponential dispersion model in the data allows for the definition of a difference detection limit (DDL) with universal applicability to systems following known dispersion. The DDL is the minimum separation between two points along a dispersion model required to claim they are different according to a particular statistical test. The DDL scales transparently with the mean and works at any location in a response function.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.7b02909DOI Listing

Publication Analysis

Top Keywords

fluctuation scaling
12
detection limit
12
dispersion model
12
standard deviation
8
horwitz scaling
8
interlaboratory studies
8
simple exponential
8
lines instruments
8
exponential dispersion
8
dispersion
5

Similar Publications

Parkinson's disease (PD) is characterized by motor and non-motor symptoms, including olfactory dysfunction. Prior studies have shown that olfaction deteriorates with disease progression, however fluctuations in olfaction and related PD symptoms have been less explored. This study aimed to investigate correlations between changes in odor identification ability and PD symptoms.

View Article and Find Full Text PDF

Background: With the increasing global focus on health and the growing popularity of natural therapies, Traditional Chinese Medicine (TCM) products, including extracts, crude drugs, and herbal preparations, are widely utilized as both primary and complementary medicines worldwide. The Regional Comprehensive Economic Partnership (RCEP), spanning 15 countries across East Asia, Southeast Asia, and Oceania, offers a vast market for TCM. However, limited research has been conducted on the complex trade relations among RCEP members.

View Article and Find Full Text PDF

Background: Guillain-Barré syndrome (GBS) presents with progressive ascending weakness, but it can also present with dysautonomia such as tachycardia, blood pressure fluctuations, diaphoresis, ileus, and urinary retention. GBS patients with dysautonomia was observed to have longer hospital stays and higher mortality rates than those without dysautonomia. We aimed to determine the risk factors for dysautonomia and its manifestations among patients with GBS and compared their features to those without dysautonomia.

View Article and Find Full Text PDF

Current use pesticides (CUPs) are recognised as the largest deliberate input of bioactive substances into terrestrial ecosystems and one of the main factors responsible for the current decline in insects in agricultural areas. To quantify seasonal insect exposure in the landscape at a regional scale (Rhineland-Palatine in Germany), we analysed the presence of multiple (93) active ingredients in CUPs across three different agricultural cultivation types (with each three fields: arable, vegetable, viticulture) and neighbouring meadows. We collected monthly soil and vegetation samples over a year.

View Article and Find Full Text PDF

Low-vibration cryogenic test facility for next generation of ground-based gravitational-wave observatories.

Rev Sci Instrum

January 2025

OzGrav-ANU, ARC Centre for Gravitational Astrophysics, College of Science, The Australian National University, Canberra ACT2601, Australia.

We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10-16m/Hz at 1 kHz. This sensitivity is necessary for future tests of thermal noise models on cross sections of silicon suspension samples proposed for future gravitational-wave detectors. A volume of ∼36 l is enclosed by radiation shields cooling an optical test cavity that is suspended from a multi-stage pendulum chain providing isolation from acoustic and environmental noise.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!