Background: As the indications for transcatheter aortic valve implantation (TAVI) have expanded, so to have the demands on interventionists to allow as many patients to access this technology as possible.

Methods: We retrospectively reviewed our TAVI database for patients who had received a 29mm SAPIEN 3 valve despite having an annular area greater than the manufacturer-recommended upper limit of 683mm, as determined by multi-detector computed tomography (MDCT). Procedural and inpatient outcome data were collected.

Results: The study population was 5 of 121 patients receiving a SAPIEN 3 valve since it became available in March 2015. Their annular area ranged from 691 to 800mm. Valve deployment was successful in all patients. The deployment balloon volume was nominal, except for an additional 1ml in one patient. No patient had a new indication for permanent pacing, and no significant valvular or paravalvular regurgitation (PVR) was identified on post-procedure transthoracic echocardiography. All patients survived to hospital discharge.

Conclusions: In this select group of patients we have demonstrated that it is safe and feasible to use the 29mm SAPIEN 3 in patients with annular dimensions greater than those recommended, with minimal balloon overfilling.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hlc.2017.08.025DOI Listing

Publication Analysis

Top Keywords

transcatheter aortic
8
aortic valve
8
valve implantation
8
patients
8
29mm sapien
8
sapien valve
8
annular area
8
valve
5
implantation patients
4
patients large
4

Similar Publications

One-year hemodynamic and clinical outcomes in self-expanding valves: Comparison of ACURATE neo2 versus ACURATE neo.

Cardiovasc Revasc Med

December 2024

Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:

Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.

View Article and Find Full Text PDF

Bioprosthetic aortic valve degeneration (BAVD) is a significant clinical concern following both transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). The increasing use of bioprosthetic valves in aortic valve replacement in younger patients and the subsequent rise in cases of BAVD are acknowledged in this review which aims to provide a comprehensive overview of the incidence, diagnosis, predictors, and management of BAVD. Based on a thorough review of the existing literature, this article provides an updated overview of the biological mechanisms underlying valve degeneration, including calcification, structural deterioration, and inflammatory processes and addresses the various risk factors contributing to BAVD, such as patient demographics, comorbidities, and procedural variables.

View Article and Find Full Text PDF

Aortic stenosis (AS) is a critical valvular heart disease associated with significant morbidity and mortality if not managed promptly. Previous studies have highlighted the "weekend effect", where the day of admission impacts outcomes in various cardiac conditions. This study evaluates the impact of weekend versus weekday admissions on outcomes in patients admitted with acutely decompensated aortic stenosis.

View Article and Find Full Text PDF

Introduction: Transcatheter aortic valve replacement (TAVR) has become a viable alternative to surgical aortic valve replacement (SAVR) for high-risk patients with aortic stenosis. One such high-risk group is patients with pulmonary hypertension (PH), which is known to increase surgical risk and adversely affect outcomes. This study aims to compare midterm and long-term survival in TAVR and SAVR among patients with PH.

View Article and Find Full Text PDF

Early safety after TAVR according to VARC-3 criteria: incidence, predictors, and clinical impact.

Rev Esp Cardiol (Engl Ed)

December 2024

Département de Cardiologie, Institut universitaire de cardiologie et de pneumologie de Québec, Université Laval, Quebec, Canada. Electronic address:

Introduction And Objectives: The Valve Academic Research Consortium (VARC)-3 definition of the early safety (ES) composite endpoint after transcatheter aortic valve replacement (TAVR) lacks clinical validation. The aim of this study was to determine the incidence, predictors, and clinical impact of ES after TAVR as defined by VARC-3 criteria.

Methods: We performed a multicenter study including 10 078 patients with severe aortic stenosis undergoing transarterial TAVR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!