Videofluoroscopy has been shown to provide essential information in the evaluation of the functionality of total knee arthroplasties. However, due to the limitation in the field of view, most systems can only assess knee kinematics during highly restricted movements. To avoid the limitations of a static image intensifier, a moving fluoroscope has been presented as a standalone system that allows tracking of the knee during multiple complete cycles of level- and downhill-walking, as well as stair descent, in combination with the synchronous assessment of ground reaction forces and whole body skin marker measurements. Here, we assess the ability of the system to keep the knee in the field of view of the image intensifier. By measuring ten total knee arthroplasty subjects, we demonstrate that it is possible to maintain the knee to within 1.8 ± 1.4 cm vertically and 4.0 ± 2.6 cm horizontally of the centre of the intensifier throughout full cycles of activities of daily living. Since control of the system is based on real-time feedback of a wire sensor, the system is not dependent on repeatable gait patterns, but is rather able to capture pathological motion patterns with low inter-trial repeatability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5633186PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0185952PLOS

Publication Analysis

Top Keywords

moving fluoroscope
8
complete cycles
8
well stair
8
stair descent
8
total knee
8
field view
8
image intensifier
8
knee
6
fluoroscope capture
4
capture tibiofemoral
4

Similar Publications

Impact of Leg Position on Measurements Used to Detect Femoral Component Subsidence in THA.

Arthroplast Today

December 2024

Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.

Background: A fully automated artificial intelligence-based tool was developed to detect and quantify femoral component subsidence between serial radiographs. However, it did not account for measurement errors due to leg position differences, such as rotation or flexion, between comparative radiographs. If there are small differences in rotation or flexion of the leg between comparative radiographs, the impact on subsidence measurement is unclear.

View Article and Find Full Text PDF
Article Synopsis
  • Early diagnosis of cardiomyopathy through endomyocardial biopsy (EMB) during cardiac implantable electronic device (CIED) implantation can lead to timely treatment and potentially resolve complications.
  • This study explored a new technique for EMB using a 3D delivery sheath, analyzing the sheath's performance and its effectiveness in obtaining biopsy samples.
  • Results showed that the 3D delivery sheaths were safe and effective, with 20% of patients diagnosed with cardiac amyloidosis, highlighting the importance of this technique in early detection.
View Article and Find Full Text PDF

We report on a 7-month-old boy (4.2 kg/60 cm) with severe immunodeficiency disorder and bacterial septicaemia who was referred for an infected atrial thrombus secondary to a jugular central line. The echocardiogram showed a teardrop-shaped thrombus with a wide base adherent to the interatrial wall and a flimsy tail moving freely in the right atrium.

View Article and Find Full Text PDF

Study Design: This was a single-center prospective clinical and radiographic analysis of pedicle screw instrumentation with Robotic-assisted navigation (RAN) and augmented reality (AR).

Objective: This study aimed to compare the accuracy of lumbosacral pedicle screw placement with RAN versus AR.

Summary Of Background Data: RAN and AR have demonstrated superior accuracy in lumbar pedicle screw placement compared to conventional free-hand techniques.

View Article and Find Full Text PDF

Introduction: Laparoscopic cholecystectomy is performed very commonly but laparoscopic common bile duct exploration (LCBDE) is performed infrequently. We aimed to determine the most significant barriers to performing LCBDE and to identify the highest yield interventions to facilitate adoption.

Methods And Procedures: A national survey was designed by content experts, who regularly perform LCBDE.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!