A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical Evaluation of an Extended Depth of Focus Intraocular Lens With the Salzburg Reading Desk. | LitMetric

Background: Clinical evaluation of an extended depth of focus (EDOF) intraocular lens (IOL) regarding visual performance at various distances, reading performance on an electronic reading desk, and depth of focus on the defocus curve.

Methods: In this prospective study, 30 eyes of 15 patients who received the Tecnis Symfony IOL (Abbott Medical Optics, Inc., Santa Ana, CA) were examined 3.60 ± 1.54 months postoperatively. Uncorrected and corrected distance (UDVA and CDVA), uncorrected and distance-corrected intermediate (UIVA and DCIVA), and uncorrected and distance-corrected near (UNVA and DCNVA) visual acuity were determined. The defocus curve was performed with distance correction. Furthermore, the reading acuity at the preferred near and intermediate distances was measured with consideration of the reading distance, speed, and print size. A subjective questionnaire was also administered.

Results: Results showed a median UDVA of 0.03 logMAR or 20/21.43 Snellen (range: 0.44 to -0.18 logMAR or 20/55.08 to 20/13.21 Snellen), UNVA of 0.20 logMAR or 20/31.70 Snellen (range: 0.46 to 0.00 logMAR or 20/57.68 to 20/20 Snellen), and UIVA of -0.03 logMAR or 20/18.67 Snellen (range: 0.14 to -0.18 logMAR or 20/27.61 to 20/13.21 Snellen). The improved performance at intermediate distance was confirmed by an uncorrected reading acuity of 0.09 logMAR or 20/24.61 Snellen (range: 0.36 to 0.00 logMAR or 20/45.82 to 20/20.00 Snellen) at a preferred intermediate distance of 64.10 cm (range: 52.0 to 75.0 cm). The defocus curve showed an extended range of visual acuity of 0.10 logMAR or better between 1.00 and -1.50 diopters.

Conclusions: The EDOF IOL design provided a wide range of improved visual and reading function between far and intermediate distances and also improved near visual acuity. Patients reported a high rate of satisfaction and spectacle independence at the various distances. [J Refract Surg. 2017;33(10):664-669.].

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20170621-08DOI Listing

Publication Analysis

Top Keywords

snellen range
16
depth focus
12
visual acuity
12
logmar
9
clinical evaluation
8
evaluation extended
8
extended depth
8
intraocular lens
8
reading desk
8
uncorrected distance-corrected
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!