Objectives/hypothesis: Cricoid fracture is a serious concern for balloon dilatation in airway stenosis. Furthermore, there are no studies examining tracheal rupture in balloon dilatation of stenotic segments. The aim of this study was to evaluate the effect of supramaximal pressures of balloons on the cricoid and tracheal rings.

Study Design: Prospective cadaveric study.

Methods: Seven cadaveric laryngotracheal complexes of normal adults with intact cricothyroid membranes were acquired. Noncompliant vascular angioplasty balloons (BARD-VIDA) were used for dilatation. The subglottis and trachea were subjected to supramaximal dilatation pressures graduated to nominal burst pressure (NBP) and, if necessary, rated burst pressure (RBP). Larger-diameter balloons, starting from 18 mm size to 24 mm, were used. Dilatations were maintained for 3 minutes.

Results: The cricoid ring was disrupted by larger-diameter balloons (22 mm and 24 mm) even at lower pressures (less than NBP) in six cases. Tracheal cartilages were very distensible, and external examination after supramaximal dilatation (24 mm close to RBP) revealed no obvious cartilage fractures or trachealis tears. Histopathological examination revealed sloughing of mucosa in the areas corresponding to balloon placement, but no microfractures or disruption of the perichondrium of tracheal ring cartilages.

Conclusions: These results indicate that the cricoid is vulnerable to injury from larger balloons even at lower dilatation pressures. The tracheal cartilages and the membranous wall of the trachea remained resilient to supramaximal dilatation and larger balloons.

Level Of Evidence: NA. Laryngoscope, 128:1304-1309, 2018.

Download full-text PDF

Source
http://dx.doi.org/10.1002/lary.26872DOI Listing

Publication Analysis

Top Keywords

balloon dilatation
12
dilatation pressures
12
supramaximal dilatation
12
dilatation
8
cricoid tracheal
8
burst pressure
8
larger-diameter balloons
8
tracheal cartilages
8
tracheal
6
pressures
5

Similar Publications

Transcatheter aortic valve repair (TAVR) presents a minimally invasive alternative to traditional surgical valve replacement, albeit not without its own set of complications. A rare complication is the infolding of the self-expanding valve, which can precipitate cardiac arrest. The estimated incidence rate of this complication stands at 1.

View Article and Find Full Text PDF

Background: Small-bowel angioectasia is commonly diagnosed and managed using double-balloon enteroscopy; however, rebleeding rates can vary significantly. This study aimed to identify and evaluate the clinical predictors of rebleeding in patients with small-bowel angioectasia.

Methods: This retrospective study focused on adult patients who underwent endoscopic management for small bowel vascular lesions (SBVLs).

View Article and Find Full Text PDF

Background: Since patients with congenital heart defects (CHD) frequently require life-long medical care and repeat invasive treatment, radiation exposure during interventional procedures is a relevant issue concerning potential radiation related risks. Therefore, an analysis on radiation data from the German Registry for Cardiac Operations and Interventions in patients with CHD was performed.

Methods: From January 2012 until December 2020 a total of 28,374 cardiac catheter interventions were recorded.

View Article and Find Full Text PDF

Background: Restorative proctocolectomy with ileal pouch-anal anastomosis (IPAA) is a common surgical procedure for ulcerative colitis and familial adenomatous polyposis. IPAA strictures are a known complication, often requiring surgical intervention. Endoscopic interventions offer a less invasive alternative, but their safety and efficacy remain uncertain.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) is a safe and effective therapy for patients with severe aortic stenosis. A Stuck leaflet and severe intraprosthetic regurgitation after valve implantation occur rarely but can lead to sudden haemodynamic deterioration. We encountered a case of a stuck leaflet following post-dilatation with the Edwards Sapien 3 Ultra RESILIA valve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!