A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optimization of a new method for extraction of cyanidin chloride and pelargonidin chloride anthocyanins with magnetic solid phase extraction and determination in fruit samples by HPLC with central composite design. | LitMetric

Here, we are reporting a sensitive, simple and rapid method for the analysis of cyanidin chloride and pelargonidin chloride anthocyanins in cherry, sour cherry, pomegranate and barberry produced in Iran. The analytes were extracted with acetonitrile-hydrochloric acid (1% v/v) mixture under optimized pretreatment conditions. Clean-up of the extract from fruits was conducted by magnetic solid phase extraction using salicylic acid functionalized silica-coated magnetite nanoparticles (SCMNPs) as the adsorbent. The optimized conditions searched with central composite design. Working under optimum conditions specified as: SCMNPs modified with salicylic acid, sorbent contact time and sample 10min, mechanical stirring time 57.3min. HPLC with UV-detection was used for determination of the analytes. The limit of detection, LOD, obtained for the two anthocyanins were 0.02 and 0.03μgg, respectively. The ranges of the spiked recoveries were 80.0-97.6 and 72.9-97.2%, with the relative standard deviations (RSD) of 2.1 and 2.5%, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2017.09.040DOI Listing

Publication Analysis

Top Keywords

cyanidin chloride
8
chloride pelargonidin
8
pelargonidin chloride
8
chloride anthocyanins
8
magnetic solid
8
solid phase
8
phase extraction
8
central composite
8
composite design
8
salicylic acid
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!