A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraobserver and Interobserver Reliability of Radiographic Analysis of Proximal Humerus Fractures in Adolescents. | LitMetric

AI Article Synopsis

  • The study addresses the inconsistency in measuring angulation for pediatric proximal humerus fractures (PHFs) and proposes a new standardized method to improve agreement among different raters.
  • Seven raters assessed 26 shoulder X-rays from patients aged 10 to 16, using both their own methods and the proposed standardized method to evaluate angulation, along with the Neer and Horowitz classification systems.
  • Results showed excellent reliability with the standardized method, while the existing classification systems displayed only fair to moderate reliability, indicating the proposed method's potential for better consistency in practice.

Article Abstract

Background: Multiple studies have shown low intrarater and interrater agreement of radiographic classification systems for proximal humerus fractures (PHFs) in adults. There is no standardized method of measuring angulation of pediatric PHFs, nor is there consensus as to the amount of angulation and displacement that require operative fixation of adolescent PHFs. We propose a new standardized method to measure fracture angulation that is similar to the method used to measure the epiphyseal-shaft angle for slipped capital femoral epiphysis. The primary purpose of this study was to evaluate the intraobserver and interobserver reliability of our proposed method compared with a nonstandardized method. The secondary purpose was to evaluate the intrarater and interrater agreement of the Neer and Horowitz (NH), and Salter-Harris (SH) classification systems.

Methods: Seven raters evaluated 26 deidentified anteroposterior shoulder radiographs of patients 10 to 16 years of age with PHFs. Raters classified each fracture using the NH and SH systems, and used their own method to measure fracture angulation. This process was repeated 2 weeks later. During the second round, raters also measured fracture angulation using our proposed standardized method. Two weeks after the second round, raters reevaluated the radiographs using the standardized method. Intraclass correlation coefficients were calculated.

Results: Excellent intraobserver and interobserver agreement was achieved for the standardized method of measuring fracture angulation. All of the raters had an intrarater reliability classified as excellent (>0.80) using the standardized method. Good intrarater and excellent interrater agreement was achieved when raters used their own fracture angulation measurement method but wide confidence intervals suggested that the results were less precise. Fair to moderate intrarater and interrater reliability was seen for the NH and SH classifications.

Conclusions: Our standardized method for measuring angulation in adolescent PHFs demonstrated excellent intrarater and interrater reliability. We propose that this technique may be a more precise method of measuring fracture angulation and this method should be used in future studies that evaluate indications for operative management of adolescent PHFs.

Level Of Evidence: Level III-diagnostic.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BPO.0000000000001083DOI Listing

Publication Analysis

Top Keywords

standardized method
28
fracture angulation
24
intrarater interrater
16
method measuring
16
method
14
intraobserver interobserver
12
interrater agreement
12
method measure
12
angulation
9
interobserver reliability
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!