Purpose: Prospective motion correction reduces artifacts in MRI by correcting for subject motion in real time, but techniques are limited for multishot 2-dimensional (2D) sequences. This study addresses this limitation by using 2D echo-planar imaging (EPI) slice navigator acquisitions together with a multislice-to-volume image registration.

Methods: The 2D-EPI navigators were integrated into 2D imaging sequences to allow a rapid, real-time motion correction based on the registration of three navigator slices to a reference volume. A dedicated slice-iteration scheme was used to limit mutual spin-saturation effects between navigator and image data. The method was evaluated using T -weighted spin echo and multishot rapid acquisition with relaxation enhancement (RARE) sequences, and its motion-correction capabilities were compared with those of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER). Validation was performed in vivo using a well-defined motion protocol.

Results: Data acquired during subject motion showed residual motion parameters within ±0.5 mm and ±0.5°, and demonstrated a substantial improvement in image quality compared with uncorrected scans. In a comparison to PROPELLER, the proposed technique preserved a higher level of anatomical detail in the presence of subject motion.

Conclusions: EPI-navigator-based prospective motion correction using multislice-to-volume image registration can substantially reduce image artifacts, while minimizing spin-saturation effects. The method can be adapted for use in other 2D MRI sequences and promises to improve image quality in routine clinical examinations. Magn Reson Med 78:2127-2135, 2017. © 2017 International Society for Magnetic Resonance in Medicine.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.26951DOI Listing

Publication Analysis

Top Keywords

motion correction
16
prospective motion
12
multislice-to-volume image
12
image registration
8
subject motion
8
spin-saturation effects
8
image quality
8
image
7
motion
7
correction
4

Similar Publications

Protein Target Search Diffusion-association/dissociation Free Energy Landscape around DNA Binding Site with Flanking Sequences.

Biophys J

January 2025

Department of Physics and Astronomy, Department of Chemistry, NSF-Simons Center for Multiscale Cell Fate Research, University of California, Irvine, California, USA. Electronic address:

In this work we present a minimal structure-based model of protein diffusional search along local DNA amid protein binding and unbinding events on the DNA, taking into account protein-DNA electrostatic interactions and hydrogen-bonding (HB) interactions or contacts at the interface. We accordingly constructed the protein diffusion-association/dissociation free energy surface and mapped it to 1D as the protein slides along DNA, maintaining the protein-DNA interfacial HB contacts that presumably dictate the DNA sequence information detection. Upon DNA helical path correction, the protein 1D diffusion rates along local DNA can be physically derived to be consistent with experimental measurements.

View Article and Find Full Text PDF

The motion of the trabecular meshwork (TM) facilitates the aqueous drainage from the anterior chamber to the venous system, thereby maintaining normal intraocular pressure. As such, characterizing the TM motion is valuable for assessing the functionality of the aqueous outflow system, as demonstrated by previous phase-sensitive optical coherence tomography (OCT) studies. Current methods typically acquire motion from a single cross-sectional plane along the circumference of the anterior chamber.

View Article and Find Full Text PDF

Purpose: To provide a fast quantitative imaging approach for a 0.55T scanner, where signal-to-noise ratio is limited by the field strength and k-space sampling speed is limited by a lower specification gradient system.

Methods: We adapted the three-dimensional spiral projection imaging MR fingerprinting approach to 0.

View Article and Find Full Text PDF

Purpose: To evaluate visibility of a sub-band posterior to the external limiting membrane (ELM) and assess its age-associated variation.

Methods: In a retrospective cross-sectional study, normal eyes were imaged using a high-resolution spectral-domain optical coherence tomography (SD-OCT) prototype (2.7-µm axial resolution).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!