A simple, rapid, and robust RP-HPLC method have been developed and validated to measure palbociclib (PB) and letrozole (LT) at single wavelength (254 nm). A isocratic elution of samples performed on Intersil C (4.6 mm × 250 mm particle size 5 μm) column with mobile phase consisting 0.02 M sodium dihydrogen phosphate buffer (pH 5.5): acetonitrile: methanol (80:10:10 v/v/v) delivered at flow rate 1.0 mL min. A good linear response was achieved over the range of 5-50 μg mL. The LODs for PB and LT were found to be 0.098 and 0.0821 µg mL, while the LOQs for PB and LT were 0.381-0.315 µg mL, respectively. The method was quantitatively evaluated in terms of system suitability test, linearity, precision, accuracy (recovery) and robustness as per standard guidelines. The method is simple, convenient and suitable for the analysis of PB and LT in bulk drug.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/15376516.2017.1388458 | DOI Listing |
J Taibah Univ Med Sci
December 2024
Department of Veterinary Pre-Clinical Science, Faculty of Veterinary Medicine, Universiti Putra Malaysia, Serdang, Selangor, Malaysia.
Objective: Concerns over the increasing number of obese individuals and the associated health risks have prompted therapeutic option explorations. Similarly, this study aimed to establish fruit extract (SCFE) anti-adipogenic attributes in 3T3-L1 cells.
Methods: The polyphenolic compounds in SCFE were identified with Reverse phase-high performance liquid chromatography (RP-HPLC).
J Chromatogr A
December 2024
Synthetic Molecule Pharmaceutical Science, gRED, Genentech, Inc., 1 DNA Way, South San Francisco, CA, 94080, United States. Electronic address:
Quantitative structure retention relation (QSRR) is an active field of research, primarily focused on predicting chromatography retention time (Rt) based on molecular structures of an input analyte on a single or limited number of reversed-phase HPLC (RP-HPLC) columns. However, in the pharmaceutical chemistry manufacturing and controls (CMC) settings, single-column QSRR models are often insufficient. It is important to translate retention time across different HPLC methods, specifically different stationary phases (SP) and mobile phases (MP), to guide the HPLC method development, and to bridge organic impurity profiles across different development phases and laboratories.
View Article and Find Full Text PDFFood Chem
December 2024
Karlsruhe Institute of Technology, Institute of Applied Biosciences, Department of Bioactive and Functional Food Chemistry, Karlsruhe, Germany; Leibniz Institute for Food Systems Biology at the Technical University of Munich, Freising, Germany; Technical University of Munich, TUM School of Life Sciences, Professorship of Food Biopolymer Systems, Freising, Germany. Electronic address:
Gluten-free products must not contain more than 20 mg/kg of gluten to be safe for consumption by celiac disease patients. Almost all analytical methods are calibrated to wheat, wheat gluten or gliadin, and there is no rye-specific reference material available. The aim of this study was to assess the effect of the harvest year on rye gluten composition and to generate distinct rye isolates to serve as calibration standards.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
January 2025
Hacettepe University, Faculty of Pharmacy, Department of Pharmaceutical Technology, Ankara 06100 Türkiye. Electronic address:
A new reversed phase high-performance liquid chromatography (RP-HPLC) method, with a short analysis time and easy to apply, was developed for the simultaneous detection of cimetidine (CIM), metoprolol tartrate (MT) and phenol red (PR) for use in intestinal perfusion studies. The analysis was performed with phosphate buffer (pH 5.0, 12.
View Article and Find Full Text PDFNat Prod Res
January 2025
Teerthanker Mahaveer College of Pharmacy, Teerthanker Mahaveer University, Moradabad, UP, India.
Embelin (EMB) and Piperine (PIP) alkaloids are reported for -antidiabetic, hypolipidemic, antioxidant, and anti-cancer properties. However, simultaneous analytical methods are scarce. A stability-indicating RP-HPLC method was developed with mobile phase MeOH: 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!