Spatio-temporal edge-aware (STEA) filtering methods have recently received increased attention due to their ability to efficiently solve or approximate important image-domain problems in a temporally consistent manner - which is a crucial property for video-processing applications. However, existing STEA methods are currently unsuited for real-time, embedded stream-processing settings due to their high processing latency, large memory, and bandwidth requirements, and the need for accurate optical flow to enable filtering along motion paths. To this end, we propose an efficient STEA filtering pipeline based on the recently proposed permeability filter (PF), which offers high quality and halo reduction capabilities. Using mathematical properties of the PF, we reformulate its temporal extension as a causal, non-linear infinite impulse response filter, which can be efficiently evaluated due to its incremental nature. We bootstrap our own accurate flow using the PF and its temporal extension by interpolating a quasi-dense nearest neighbour field obtained with an improved PatchMatch algorithm, which employs binarized octal orientation maps (BOOM) descriptors to find correspondences among subsequent frames. Our method is able to create temporally consistent results for a variety of applications such as optical flow estimation, sparse data upsampling, visual saliency computation and disparity estimation. We benchmark our optical flow estimation on the MPI Sintel dataset, where we currently achieve a Pareto optimal quality-efficiency tradeoff with an average endpoint error of 7.68 at 0.59 s single-core execution time on a recent desktop machine.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TIP.2017.2757259DOI Listing

Publication Analysis

Top Keywords

optical flow
12
stea filtering
8
temporally consistent
8
temporal extension
8
flow estimation
8
edge-aware spatio-temporal
4
filtering
4
spatio-temporal filtering
4
filtering real-time
4
real-time spatio-temporal
4

Similar Publications

Solitary foraging insects like desert ants rely heavily on vision for navigation. While ants can learn visual scenes, it is unclear what cues they use to decide if a scene is worth exploring at the first place. To investigate this, we recorded the motor behavior of Cataglyphis velox ants navigating in a virtual reality set-up (VR) and measured their lateral oscillations in response to various unfamiliar visual scenes under both closed-loop and open-loop conditions.

View Article and Find Full Text PDF

Objective: Elevated intracranial pressure (ICP), a common complication in traumatic brain injuries (TBI), can lead to optic nerve sheath diameter (ONSD) enlargement and flow spectrum changes from the internal carotid artery (ICA) to middle cerebral artery (MCA). This study will investigate the use of Cervical-Cerebral Arterial Ultrasound (CCAU) for non-invasive ICP assessment and evaluating the related indices' clinical utility in TBI patients with decompressive craniotomy (DC).

Methods: ONSD and flow spectrum changes were measured within 24 h after DC in 106 patients via ultrasonic ONSD measurement and CCAU, simultaneously.

View Article and Find Full Text PDF

Aptamer-Antibody Birecognized Sandwich SERRS Biosensor in Accurate and Rapid Identification of Intraoperative Parathyroid Hormone.

Anal Chem

January 2025

State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, College of Energy, Discipline of Intelligent Instrument and Equipment, Cancer Center and Department of Breast and Thyroid Surgery, Department of Ultrasound, Xiang'an Hospital of Xiamen University, School of Medicine, Laboratory Animal Center Xiamen University, Xiamen University, Xiamen 361005, China.

With the increasing incidence of thyroid cancer worldwide and the increasing demand for surgery, the risk of parathyroid injury is also increasing, which will lead to postoperative hypoparathyroidism (HP) and hypocalcemia. In order to improve the quality of life of patients after surgery, there is an urgent need to develop a novel platform that can identify the parathyroid gland immediately during surgery. The parathyroid gland promotes the increase of blood calcium concentration by secreting parathyroid hormone (PTH).

View Article and Find Full Text PDF

An integrated immunofluorescent detection system for automated and sensitive protein quantification based on a microfluidic flow cytometry platform.

Anal Chim Acta

March 2025

Holosensor Medical Technology Ltd, Room 12, No. 1798, Zhonghuayuan West Road, Yushan Town, Suzhou, 215000, China; Department of Veterinary Medicine, University of Cambridge, Cambridge, UK. Electronic address:

Rapid and sensitive protein detection methods are of benefit to clinical diagnosis, pathological mechanism research, and infection prevention. However, routine protein detection technologies, such as enzyme-linked immunosorbent assay and Western blot, suffer from low sensitivity, poor quantification and labourious operation. Herein, we developed a fully automated protein analysis system to conduct fast protein quantification at the single molecular level.

View Article and Find Full Text PDF

Purpose: Trophoblast cell-surface antigen 2 (Trop2) is overexpressed in various solid tumors and contributes to tumor progression, while its expression remains low in normal tissues. Trop2-targeting antibody-drug conjugate (ADC), sacituzumab govitecan-hziy (Trodelvy), has shown efficacy in targeting this antigen. Leveraging the enhanced specificity of ADCs, we conducted the first immunoPET imaging study of Trop2 expression in gastric cancer (GC) and triple-negative breast cancer (TNBC) models using Zr-labeled Trodelvy ([Zr]Zr-DFO-Trodelvy).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!