A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multimodal Super-resolution Optical Microscopy Using a Transition-Metal-Based Probe Provides Unprecedented Capabilities for Imaging Both Nuclear Chromatin and Mitochondria. | LitMetric

Multimodal Super-resolution Optical Microscopy Using a Transition-Metal-Based Probe Provides Unprecedented Capabilities for Imaging Both Nuclear Chromatin and Mitochondria.

J Am Chem Soc

Central Laser Facility, Rutherford Appleton Laboratory, Research Complex at Harwell, Science and Technology Facilities Council , Harwell-Oxford, Didcot OX11 0QX, United Kingdom.

Published: November 2017

Detailed studies on the live cell uptake properties of a dinuclear membrane-permeable Ru cell probe show that, at low concentrations, the complex localizes and images mitochondria. At concentrations above ∼20 μM, the complex images nuclear DNA. Because the complex is extremely photostable, has a large Stokes shift, and displays intrinsic subcellular targeting, its compatibility with super-resolution techniques was investigated. It was found to be very well suited to image mitochondria and nuclear chromatin in two color, 2C-SIM, and STED and 3D-STED, both in fixed and live cells. In particular, due to its vastly improved photostability compared to that of conventional SR probes, it can provide images of nuclear DNA at unprecedented resolution.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jacs.7b08772DOI Listing

Publication Analysis

Top Keywords

nuclear chromatin
8
images nuclear
8
nuclear dna
8
multimodal super-resolution
4
super-resolution optical
4
optical microscopy
4
microscopy transition-metal-based
4
transition-metal-based probe
4
probe unprecedented
4
unprecedented capabilities
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!