A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of non-invasive blood pressure measurement intervals on the occurrence of intra-operative hypotension. | LitMetric

The American Society of Anesthesiologists Standards for Basic Monitoring recommends blood pressure (BP) measurement every 5 min. Research has shown distractions or technical factors can cause prolonged measurement intervals exceeding 5 min. We investigated the relationship between prolonged non-invasive BP (NIBP) measurement interval and the incidence of hypotension, detected post-interval. Our secondary outcome was to determine independent predictors of these prolonged NIBP measurement intervals. Retrospective data were analyzed from 139,509 general anesthesia cases from our institution's Anesthesia Information Management System (AIMS). Absolute hypotension (AH) was defined a priori as a systolic BP < 80 mmHg and relative hypotension (RH) was defined as a 40% decrease in systolic BP from the preoperative baseline. Odds ratios (OR) with 95% confidence intervals and Pearson's Chi square Test reported the association of prolonged NIBP measurement intervals on hypotension detected post-NIBP measurement interval. Logistic regression models were developed to determine independent predictors of NIBP measurement intervals. The analysis revealed that NIBP measurement intervals greater than 6 and 10 min are associated with an approximately four times higher incidence of a patient transitioning into hypotension (AH/RH > 6 min OR 4.0 / 3.6; AH/RH > 10 min OR 4.3 / 3.9; p < 0.001). A key finding was that the "> 10-minute AH model" indicated that age 41-80, increased co-morbidity profile, obesity and turning (repositioning) of the operative room table were significant predictors of prolonged NIBP measurement intervals (p < 0.001). While we do not suggest NIBP measurement intervals cause hypotension, intervals greater than 6 and 10 min are associated with a fourfold increase in the propensity of an undetected transition into both RH or AH. These data support current monitoring guidelines.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6138874PMC
http://dx.doi.org/10.1007/s10877-017-0065-4DOI Listing

Publication Analysis

Top Keywords

measurement intervals
12
blood pressure
8
pressure measurement
8
nibp measurement
8
measurement
5
influence non-invasive
4
non-invasive blood
4
intervals occurrence
4
occurrence intra-operative
4
intra-operative hypotension
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!