Comparative analysis of condom lubricants on pre & post-coital vaginal swabs using AccuTOF-DART.

Forensic Sci Int

Florida Institute of Technology, Department of Chemistry, 150 W. University Blvd., 323 Olin Physical Sciences Building, Melbourne, FL 32901, United States. Electronic address:

Published: November 2017

In this study we demonstrate the use of Direct Analysis in Real Time Mass Spectrometry (DART) as a powerful tool for detection of nonoxynol in vaginal fluid post contact with a condom, enabling rapid tracing and added evidences in sexual assault crimes. Vaginal fluid was sampled using cotton swabs and glass rods and measured directly with DART. Sample preparation using water, hexane, methanol, and dichloromethane extraction, was explored for comparison and optimization of signals. Nonoxynol was detected up to eight hours after sampling. Optimal sampling conditions and mass spectrometry parameters are reported and discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.forsciint.2017.09.005DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
8
vaginal fluid
8
comparative analysis
4
analysis condom
4
condom lubricants
4
lubricants pre
4
pre post-coital
4
post-coital vaginal
4
vaginal swabs
4
swabs accutof-dart
4

Similar Publications

Introduction: Evidence to support intra-operative lidocaine infusion regimens in patients with obesity is lacking, risking underdosing or toxicity. We aimed to measure the plasma concentrations of lidocaine and its active metabolites to develop a pharmacokinetic model and optimised dosing regimen in patients with obesity.

Methods: A standardised weight-based intravenous lidocaine regimen was administered to patients with a BMI ≥ 30 kg.

View Article and Find Full Text PDF

Tetraspanin CD81 serves as a functional entry factor for porcine circovirus type 2 infection.

J Virol

December 2024

Key Laboratory of Animal Disease Diagnostics and Immunology, Ministry of Agriculture, MOE International Joint Collaborative Research Laboratory for Animal Health & Food Safety, College of Veterinary Medicine, Nanjing Agricultural University, Nanjing, Jiangsu, China.

Porcine circovirus type 2 (PCV2) is the primary causative agent of porcine circovirus-associated disease, clinically resulting in immunosuppression and co-infections with other pathogens in infected pigs. The mechanism of PCV2 infection remains unclear. In this study, we firstly found that the tetraspanin CD81 in PK-15 cells interacts with PCV2 Cap protein by using virus overlay protein-binding assay combined with mass spectrometry.

View Article and Find Full Text PDF

Unlabelled: APC 4099, isolated from bees' gut, has been identified as a promising candidate for food biopreservation. Antimicrobial activity screening revealed a broad-spectrum inhibition potential, ranging from gram-positive pathogenic bacteria to fungi responsible for food spoilage. Genomic analysis identified biosynthetic gene clusters coding for several antimicrobial peptides and secondary metabolites.

View Article and Find Full Text PDF

Chronic Kidney Disease (CKD) is one of the most common conditions affecting felines, yet the metabolic alterations underlying its pathophysiology remain poorly understood, hindering progress in identifying biomarkers and therapeutic targets. This study aimed to provide a comprehensive view of metabolic changes in feline CKD across conserved biochemical pathways and evaluate their progression throughout the disease continuum. Using a multi-biomatrix high-throughput metabolomics approach, serum and urine samples from CKD-affected cats ( = 94) and healthy controls ( = 84) were analyzed with ultra-high-performance liquid chromatography-high-resolution mass spectrometry.

View Article and Find Full Text PDF

Objectives: An analytical protocol based on isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS), which includes a peptide-based calibration strategy, was developed and validated for the determination of cardiac troponin I (cTnI) levels in clinical samples. Additionally, the developed method was compared with a protein-based calibration strategy, using cTnI serving as a model for low-abundant proteins. The aim is to evaluate new approaches for protein quantification in complex matrices, supporting the metrology community in implementing new methods and developing fit-for-purpose SI- traceable peptide or protein primary calibrators.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!