Background: Although several types of staplers have been developed, staple-line leaks have been a great problem in gastrointestinal surgery. Powered linear staplers were recently developed to further reduce the risk of tissue trauma during laparoscopic surgery. The aim of this study was to identify the factors that predict staple malformation and determine the effect of precompression and slow firing on the staple formation of this novel powered stapling method.

Methods: Porcine stomachs were divided using an endoscopic powered linear stapler with gold reloads. We divided the specimens into 9 groups according to the precompression time (0/60/180 seconds) and firing time (0/60/180 seconds). The occurrence and length of laceration and the shape of the staples were evaluated. We examined the factors influencing successful stapling and investigated the key factors for staple malformation.

Results: Precompression significantly decreased the occurrence and length of serosal laceration. Precompression and slow firing significantly improved the optimal stapling formation rate. Univariate analysis showed that the precompression time (0 seconds), firing time (0 seconds), and presence of serosal laceration were significantly associated with a low optimal formation rate. Multivariate analysis showed that these three factors were associated independently with low optimal formation rate and that the presence of serosal laceration was the only factor that could be detected during the stapling procedure.

Conclusions: We have shown that serosal laceration is a predictor of staple malformation and demonstrated the importance of precompression and slow stapling when using the powered stapling method.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1553350617733350DOI Listing

Publication Analysis

Top Keywords

serosal laceration
20
powered linear
12
staple malformation
12
precompression slow
12
formation rate
12
linear stapler
8
predictor staple
8
staplers developed
8
slow firing
8
powered stapling
8

Similar Publications

A term newborn presented after birth with abdominal distension and vomiting in a developing country in Asia. Ultrasonography suggested intestinal obstruction and abdominal X-ray showed a 'double-bubble' sign suggestive of intestinal atresia. The newborn was diagnosed with early-onset neonatal sepsis secondary to intestinal obstruction and transferred to the neonatal intensive care unit.

View Article and Find Full Text PDF

Introduction: Ruptured post-traumatic pseudoaneurysms of the superior mesenteric artery (SMA) are potentially life threatening and rarely reported in the paediatric population. The purpose of this report is to highlight the potential of endovascular treatment in this age group.

Report: A 16 year old male presented to the emergency department (ED) with seizure like activity.

View Article and Find Full Text PDF

A Novel Nonelectrosurgical Technique for Incising the Pylorus in Laparoscopic Pyloromyotomy.

J Laparoendosc Adv Surg Tech A

February 2018

1 Division of Pediatric Surgery, King Abdullah University Hospital, Jordan University of Science and Technology School of Medicine, Irbid, Jordan .

Objective: Since the loss of the protected arthrotomy knife several years ago, pediatric surgeons have struggled to find a safe, reliable, and inexpensive way to incise the pyloric serosa before spreading the muscle. The most widely accepted method of cutting the serosa is with electrocautery, although some still question its safety. We introduce a novel technique of incising the serosa with a percutaneously inserted needle without the use of electrocautery.

View Article and Find Full Text PDF

Background: Although several types of staplers have been developed, staple-line leaks have been a great problem in gastrointestinal surgery. Powered linear staplers were recently developed to further reduce the risk of tissue trauma during laparoscopic surgery. The aim of this study was to identify the factors that predict staple malformation and determine the effect of precompression and slow firing on the staple formation of this novel powered stapling method.

View Article and Find Full Text PDF

Uterine rupture, a complete disruption of uterine wall, is synonymously used of intrapartum uterine corpus injuries. However, uterine laceration, partial and minor myometrial tear, is not well characterized. A 35-year-old Japanese woman with unscarred uterus was delivered of a baby at 38 gestational weeks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!