Purpose: To compare changes in clinical (bleeding on probing [BOP] and probing pocket depth [PPD]), radiographic (crestal bone loss [CBL]), and immunologic inflammatory (interleukin-1beta [IL-1β] and matrix metalloproteinase-9 [MMP-9]) parameters around crestally and subcrestally placed dental implants 5 years after implant placement.

Materials And Methods: Fifty-two patients were divided into 2 groups: group 1 (n = 27): patients with single implants placed approximately 2 mm below the alveolar crest; group 2 (n = 25): patients with single implants placed at bone level. In both groups, peri-implant BOP, PPD, and CBL were measured, and levels of IL-1β and MMP-9 were determined in duplicates using enzyme-linked immunosorbent assay. Full-mouth debridement was performed biannually in both groups. Statistical analysis was performed using the Mann-Whitney U test (significance set at p < 0.05).

Results: All measurements in groups 1 and 2 were performed 5.3 ± 0.2 and 5.2 ± 0.1 years after implant placement, respectively. The mean CBL was 1.2 ± 0.2 mm and 1.4 ± 0.2 mm in groups 1 and 2, respectively. There was no significant difference in mean BOP, PPD, CBL and in levels of IL-1β, and MMP-9 among implants in both groups.

Conclusion: Clinical, radiographic, and immunologic inflammatory parameters are comparable around crestally and subcrestally placed single dental implants up to 5 years after placement. The depth of implant placement appears to have no effect on clinical status and performance of single dental implants.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.12637DOI Listing

Publication Analysis

Top Keywords

dental implants
16
immunologic inflammatory
12
crestally subcrestally
12
clinical radiographic
8
radiographic immunologic
8
inflammatory parameters
8
parameters crestally
8
subcrestally dental
8
implants years
8
years implant
8

Similar Publications

The aim of this study was to evaluate the mechanical properties and degree of conversion of a novel 3D-printing model resin and compare it to eight commercially available model resins. An experimental resin formulated by our proprietary resin technology along with DentaModel, NextDent 2, KeyModel Ultra, Rodin Model, Die and Model 2, DMR III, LCD Grey, and Grey Resin were used in this study. Parallelepiped specimens (2 × 2 × 25 mm, n = 5) were printed and measured for their flexural strength (FS), flexural modulus (FM), and modulus of resilience (MR) in accordance with ISO-4049.

View Article and Find Full Text PDF

Biosynthesis and Characterization of Silver Nanoparticles and Simvastatin Association in Titanium Biofilms.

Pharmaceuticals (Basel)

November 2024

Laboratório de Farmacologia de Antimicrobianos e Microbiologia, Faculdade de Ciências Farmacêuticas, Universidade Estadual de Campinas (UNICAMP), Campinas 13083-970, Brazil.

Introduction: Simvastatin is an antilipidemic drug that has already demonstrated antibacterial activities on oral and non-oral microorganisms. Silver nanoparticles also exhibit antimicrobial properties, particularly for coating implant surfaces. In this study, we evaluated the effects of combining simvastatin with silver nanoparticles on the formation and viability of biofilms consolidated on titanium discs.

View Article and Find Full Text PDF

Implant Surface Decontamination Methods That Can Impact Implant Wettability.

Materials (Basel)

December 2024

Department of Prosthodontics and Digital Technology, School of Dental Medicine, Stony Brook University, Stony Brook, NY 11794, USA.

This review addresses the effects of various decontamination methods on the wettability of titanium and zirconia dental implants. Despite extensive research on surface wettability, there is still a significant gap in understanding how different decontamination techniques impact the inherent wettability of these surfaces. Although the literature presents inconsistent findings on the efficacy of decontamination methods such as lasers, air-polishing, UV light, and chemical treatments, the reviewed studies suggest that decontamination alters in vitro hydrophilicity.

View Article and Find Full Text PDF

Exploring the Broad Spectrum of Titanium-Niobium Implants and Hydroxyapatite Coatings-A Review.

Materials (Basel)

December 2024

The Interdisciplinary Center for Dental Research and Development, Faculty of Dental Medicine, "Carol Davila" University of Medicine and Pharmacy, 19-21 Jean Louis Calderon Street, 020021 Bucharest, Romania.

Tooth loss replacement using dental implants is becoming more frequent. Traditional dental implant materials such as commercially pure titanium and titanium aluminum vanadium alloys have well-proven mechanical and biological properties. New titanium alloying metals such as niobium provide improved mechanical properties such as lower elastic modulus while displaying comparable or even better biocompatibility.

View Article and Find Full Text PDF

Development and Prevention of Biofilm on Cochlear Implants: A Systematic Review.

Medicina (Kaunas)

November 2024

1st Department of Pharmacology, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.

Biofilm formation on cochlear implants (CIs) poses a major problem for surgeons, leading to a high incidence of explantation and revision surgery. Therefore, developing appropriate and cost-effective biofilm detection and prevention techniques is of the essence. In this systematic review, we sought to investigate the development of biofilm formation on CIs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!