Objective: This study was a prospective, randomized controlled trial of rapid sequence intubation (RSI) with cricoid pressure (CP) within the emergency department (ED). The primary aim of the study was to examine the link between ideal CP and the incidence of aspiration.
Method: Patients > 18 years of age undergoing RSI in the ED of two hospitals in New South Wales, Australia, were randomly assigned to receive measured CP using weighing scales to target the ideal CP range (3.060-4.075 kg) or control CP where the weighing scales were used, but the CP operator was blinded to the amount of CP applied during the RSI. A data logger recorded all CP delivered during each RSI. Immediately after intubation, tracheal and esophageal samples were taken and underwent pepsin analysis.
Results: Fifty-four RSIs were analyzed (25 measured/29 control). Macroscopic contamination of the larynx at RSI was observed in 14 patients (26%). During induction (0-50 seconds), both groups delivered in-range CP. During intubation (51-223 seconds), laryngoscopy was associated with a reduction in mean CP below 3.060 kg in both groups. When compared, there was no statistically significant difference between the groups. For 11 patients, pepsin was detected in the oropharyngeal sample, while three were positive for tracheal pepsin. Seven patients (four control/three measured) were treated for clinical aspiration during hospitalization. As a result of the finding that neither group could maintain ideal range CP during laryngoscopy, the trial was abandoned.
Conclusion: Laryngoscopy provides a counter force to CP, which is negated to facilitate tracheal intubation. The concept that a static 3.060 to 4.075 kg CP could be maintained during laryngoscopy and intubation was rejected by our study. Whether a lower CP range could prevent aspiration during RSI was not explored by this study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/acem.13326 | DOI Listing |
Eur J Anaesthesiol
November 2024
From the Department of Anaesthesia and Intensive Care, Post Graduate Institute of Medical Education and Research (AM, VA, GDP, PJM), Biomedical Instrumentation Unit, Council of Scientific and Industrial Research - Central Scientific Instruments Organization (CSIR-CSIO), Chandigarh, Punjab, India (NK).
Background: The inability to measure the force applied during cricoid pressure is an important limitation in clinical practice. We developed a novel device to measure this force and provide real-time feedback to the operator.
Objectives: To test the hypothesis of superior oesophageal occlusion during cricoid pressure when guided by the novel device as compared with conventional practice.
Saudi J Anaesth
June 2024
Department of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, Ohio, USA.
Background: The use of cuffed endotracheal tubes (ETTs) has become the standard of care in pediatric practice. The rationale for the use of a cuffed ETT is to minimize pressure around the cricoid while providing an effective airway seal. However, safe care requires that the cuff lie distal to the cricoid ring following endotracheal intubation.
View Article and Find Full Text PDFEur J Cardiothorac Surg
June 2024
Department of Thoracic Surgery, Medical University of Vienna, Vienna, Austria.
Objectives: Treatment options for benign subglottic stenosis include endoscopic techniques or open surgery. Although endoscopic treatment is less invasive, a considerable proportion of patients develop recurrent stenosis. Endoscopic pretreatments do not exclude patients from a later surgical repair; however, the impact of previous endoscopic treatment attempts on functional outcome after open surgery is unknown.
View Article and Find Full Text PDFJ Cardiothorac Vasc Anesth
August 2024
Department of Anesthesiology, Intensive Care Medicine and Pain Medicine; Division of Cardiac-, Thoracic-, and Vascular Anesthesia and Intensive Care Medicine, Medical University of Vienna, Austria. Electronic address:
Digestion
August 2024
Department of Gastroenterology, Kitasato University of Medicine, Sagamihara, Japan.
Introduction: Esophagogastroduodenoscopy (EGD) requires adequate air infusion. However, cases of poor gastrointestinal wall extension due to frequent eructation have been reported. Sufficient gastrointestinal wall extension can be achieved by applying cricoid pressure during EGD.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!