Surgical removal of impacted mandibular third molar is a routine procedure in oral surgery. Various iatrogenic complications related to the procedure has been discussed well in the literatures before. Some of these complications are related to the wrong usage of instruments and techniques. Here we discuss a rare complication on a 42-year-old male, related to the use of high-speed handpiece drill in mandibular third molar removal in a general dental office setting. He was referred when a high speed tungsten carbide bur was accidentally broken and displaced into the mandibular bone during surgical procedure. It is not common to use a high-speed handpiece in impacted third molar removal. This iatrogenic complication could have been totally avoided with the use of proper equipment and technique; therefore raising awareness regarding wrong usage of instrument is vital to avoid similar incidents in the future.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5747789PMC
http://dx.doi.org/10.1136/bcr-2017-221892DOI Listing

Publication Analysis

Top Keywords

third molar
16
molar removal
12
mandibular third
8
wrong usage
8
high-speed handpiece
8
iatrogenic displacement
4
displacement high-speed
4
high-speed bur
4
third
4
bur third
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!