Objectives To evaluate the novel Phoenix Atherectomy System as percutaneous treatment of de novo and restenotic infrainguinal arterial lesions. Methods This prospective, multicenter, nonrandomized investigational device exemption trial was conducted across 16 US and German centers between August 2010 and April 2013. Intention-to-treat enrollment was 128 patients (mean age: 71.8 years, 59% male) with 149 lesions (mean length: 34 mm, mean diameter stenosis: 89.5%), and the primary analysis per-protocol population consisted of 105 patients with 123 lesions. The primary efficacy endpoint, technical success, was the achievement of acute debulking with a post-atherectomy residual diameter stenosis ≤50% (before adjunctive therapy). The primary safety endpoint was the major adverse event (MAE) rate through 30 days. Results For the primary analysis per-protocol population, the rate of lesion technical success was 95.1% (117/123), with the lower limit of the 95% CI 90.6%, meeting the prospectively established target performance goal of ≥86%. After post-atherectomy adjunctive therapy, residual stenosis was ≤30% for 99.2% (122/123) of lesions (mean final diameter stenosis 10.5%). Improvement of ≥1 Rutherford class occurred for 74.5% of patients through 30 days and for 80% through six months. MAEs were experienced by 5.7% (6/105) of patients through 30 days (with the upper limit of the 95% CI 11.0%, meeting the target performance goal of <20%), and 16.8% through six months. Six-month freedom from TLR and TVR was 88.0% and 86.1%, respectively. Conclusions Based on the high rate of technical success and the low rates of MAEs through six months, the Phoenix Atherectomy System is safe and effective for the debulking of lower-extremity arterial lesions. ClinicalTrials.gov identifier NCT01541774.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714160PMC
http://dx.doi.org/10.1177/1708538117712383DOI Listing

Publication Analysis

Top Keywords

diameter stenosis
12
phoenix atherectomy
8
atherectomy system
8
prospective multicenter
8
primary analysis
8
analysis per-protocol
8
per-protocol population
8
technical success
8
adjunctive therapy
8
limit 95%
8

Similar Publications

Background: Coronary Artery Disease (CAD) is a leading cause of mortality, with an increasing number of patients affected by coronary artery stenosis each year. Coronary angiography (CAG) is commonly employed as the definitive diagnostic tool for identifying coronary artery stenosis. Physician Visual Assessment (PVA) is often used as the primary method to determine the need for further intervention, but its subjective nature poses challenges.

View Article and Find Full Text PDF

Background: Extubation of the coronary guiding catheter may affect flow and pressure measurements in the coronary vessel during invasive coronary angiography (ICA).

Aim: This study aims to investigate the impact of guiding catheter extubation on fractional flow reserve (FFR), coronary flow reserve (CFR), and the index of microcirculatory resistance (IMR).

Methods: This predefined subgroup analysis of the Dan-NICAD 2 study included patients with chronic coronary syndrome referred to ICA based on a coronary computed tomography angiography.

View Article and Find Full Text PDF

Age-dependent changes in diameters of abdominal visceral arteries in children.

Jpn J Radiol

December 2024

Faculty of Medicine, Department of Pediatric Surgery, Van Yüzüncü Yil University, Van, Turkey.

Purpose: The diameters of the abdominal aorta and its branches are affected by demographic properties of patients like age, sex or body mass index. Some researchers use the body of the first lumbar vertebra (L1) as an anatomical indicator to create an exact standard for diagnosing arterial aneurysms or stenoses. In this regard, this work designed to uncover relations of abdominal visceral arteries with L1 in normal children using their abdominopelvic computed tomography images.

View Article and Find Full Text PDF

Background: Dialysis Access (DA) stenosis impacts hemodialysis efficiency and patient health, necessitating exams for early lesion detection. Ultrasound is widely used due to its non-invasive, cost-effective nature. Assessing all patients in large hemodialysis facilities strains resources and relies on operator expertise.

View Article and Find Full Text PDF

Bicuspid aortic valve (BAV), the most common congenital cardiac anomaly, predisposes individuals to aortic stenosis and regurgitation due to valve degeneration. Abnormal hemodynamics, arterial wall characteristics, and genetic factors contribute to ascending aorta dilatation, potentially leading to severe complications like aortic dissection. Presently, the most recent guidelines propose that individuals with BAV requiring valve replacement due to valve dysfunction should undergo simultaneous replacement of the ascending aorta when the diameter of aortic dilatation exceeds 4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!