OBJECTIVE To assess 3-D geometry of the humerus of dogs and determine whether the craniocaudal canal flare index (CFI) is associated with specific geometric features. SAMPLE CT images (n = 40) and radiographs (38) for 2 groups of skeletally mature nonchondrodystrophic dogs. PROCEDURES General dimensions (length, CFI, cortical thickness, and humeral head offset), curvature (shaft, humeral head, and glenoid cavity), version (humeral head and greater tubercle), and torsion were evaluated on CT images. Dogs were allocated into 3 groups on the basis of the craniocaudal CFI, and results were compared among these 3 groups. The CT measurements were compared with radiographic measurements obtained for another group of dogs. RESULTS Mean ± SD humeral head version was -75.9 ± 9.6° (range, -100.7° to -59.4°). Mean mechanical lateral distal humeral angle, mechanical caudal proximal humeral angle, and mechanical cranial distal humeral angle were 89.5 ± 3.5°, 50.2 ± 4.5°, and 72.9 ± 7.8°, respectively, and did not differ from corresponding radiographic measurements. Mean humeral curvature was 20.4 ± 4.4° (range, 9.6° to 30.5°). Mean craniocaudal CFI was 1.74 ± 0.18 (range, 1.37 to 2.10). Dogs with a high craniocaudal CFI had thicker cranial and medial cortices than dogs with a low craniocaudal CFI. Increased body weight was associated with a lower craniocaudal CFI. Radiographic and CT measurements of craniocaudal CFI and curvature differed significantly. CONCLUSIONS AND CLINICAL RELEVANCE CT-based 3-D reconstructions allowed the assessment of shaft angulation, torsion, and CFI. Radiographic and CT measurements of shaft curvature and CFI may differ.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.78.10.1140DOI Listing

Publication Analysis

Top Keywords

craniocaudal cfi
24
humeral head
16
radiographic measurements
16
humeral angle
12
cfi
10
canal flare
8
skeletally mature
8
mature nonchondrodystrophic
8
nonchondrodystrophic dogs
8
humeral
8

Similar Publications

Effect of Stem Positioning on Biomechanical Performance of a Novel Cementless Short-Stem Canine Total Hip Implant.

Vet Comp Orthop Traumatol

January 2022

Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, United States.

Objective:  The aim of this study was to evaluate the effect of stem positioning on the biomechanical performance of a novel, collared, short-stem total hip implant under compression and torsion .

Study Design:  Six canine cadaveric femurs were implanted with a collared short-stem femoral implant. Canal flare index (CFI), stem angle, absolute and relative cut heights and relative size were measured radiographically and used as independent variables.

View Article and Find Full Text PDF

Radiographic and Biomechanical Assessment of Three Implant Designs for Canine Cementless Total Hip Replacement.

Vet Comp Orthop Traumatol

November 2020

Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, United States.

Objective:  The aim of this study was to evaluate the relationship between radiographic fit/fill measurements and biomechanical performance of three canine cementless total hip implant designs using an biomechanical testing protocol that replicates compression and torsion.

Study Design:  Eighteen (six/group) canine cadaveric femurs were implanted with one of three cementless total hip implant designs: (1) collarless, (2) collared or (3) lateral bolt stems. Femoral length, canal flare index (CFI), canal fill, stem fit, stem level and stem angle were measured as independent variables.

View Article and Find Full Text PDF

Accuracy in Determining Canal Flare Index Using Different Radiographical Positions for Imaging Canine Femurs.

Vet Comp Orthop Traumatol

May 2019

Department of Veterinary Clinic and Surgery, Faculty of Agrarian and Veterinary Sciences, São Paulo State University, Jaboticabal, São Paulo, Brazil.

Objective:  The aim of this study was to compare accuracy of femoral measurements obtained from different radiographical positions with actual femoral anatomical dimensions in dogs.

Materials And Methods:  Craniocaudal projections of the femur in ventrodorsal position, standard craniocaudal radiographical (SR) and craniocaudal radiography with horizontal radiographical beam (HR), in addition to anatomical macroscopic measurements (A), were obtained from 45 femurs from 23 canine cadavers, for calculation of the canal flare index (CFI). The differences between the radiographical positions and 95% limits of agreement (LOA) between the CFI-SR, CFI-HR and CFI-A were evaluated by the Bland-Altman method.

View Article and Find Full Text PDF

OBJECTIVE To assess 3-D geometry of the humerus of dogs and determine whether the craniocaudal canal flare index (CFI) is associated with specific geometric features. SAMPLE CT images (n = 40) and radiographs (38) for 2 groups of skeletally mature nonchondrodystrophic dogs. PROCEDURES General dimensions (length, CFI, cortical thickness, and humeral head offset), curvature (shaft, humeral head, and glenoid cavity), version (humeral head and greater tubercle), and torsion were evaluated on CT images.