Recent studies suggest that dual-frequency intravascular ultrasound (IVUS) transducers allow detection of superharmonic bubble signatures, enabling acoustic angiography for microvascular and molecular imaging. In this paper, a dual-frequency IVUS cylindrical array transducer was developed for real-time superharmonic imaging. A reduced form-factor lateral mode transmitter (2.25MHz) was used to excite microbubbles effectively at 782kPa with single-cycle excitation while still maintaining the small size and low profile (5Fr) (3Fr=1mm) for intravascular imaging applications. Superharmonic microbubble responses generated in simulated microvessels were captured by the high frequency receiver (30MHz). The axial and lateral full-width half-maximum of microbubbles in a 200-μm-diameter cellulose tube were measured to be 162μm and 1039μm, respectively, with a contrast-to-noise ratio (CNR) of 16.6dB. Compared to our previously reported single-element IVUS transducers, this IVUS array design achieves a higher CNR (16.6dBvs 11dB) and improved axial resolution (162μmvs 616μm). The results show that this dual-frequency IVUS array transducer with a lateral-mode transmitter can fulfill the native design requirement (∼3-5Fr) for acoustic angiography by generating nonlinear microbubble responses as well as detecting their superharmonic responses in a 5Fr form factor.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5659895 | PMC |
http://dx.doi.org/10.1016/j.ultras.2017.09.012 | DOI Listing |
Sensors (Basel)
December 2024
Department of Electrical and Computer Engineering, Bucknell University, Lewisburg, PA 17837, USA.
Micropillar array electrodes offer several advantages, such as enhanced mass transport, lower detection limits, and the potential for miniaturization, making them instrumental in the design and fabrication of electrochemical biosensors. The performance of these biosensors is influenced by electrode geometry, including parameters like shape and height, which affect surface area and overall sensitivity. In this study, we designed a microfluidic electrochemical biosensor featuring micropillar array electrodes, modeled in COMSOL Multiphysics.
View Article and Find Full Text PDFAdv Sci (Weinh)
December 2024
Engineering Product Development, Singapore University of Technology and Design, Singapore, 487372, Singapore.
Spatially selective imaging (SSI) involves sampling a group of pixels from different positions on an encoded object to display a decoded image. Here, SSI is achieved by using off-axis cylindrical Fresnel lens arrays to decode multiple images from an encoded print of structural color pixels. Each image is optically retrieved by separately placing different "keys" (arrays of lenses in different pseudorandom configurations) over the same encoded print, and then each image is digitally reconstructed for visualization.
View Article and Find Full Text PDFSensors (Basel)
November 2024
Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
The rise of CubeSats has unlocked opportunities for cutting-edge space missions with reduced costs and accelerated development timelines. CubeSats necessitate a high-gain antenna that can fit within a tightly confined space. This paper is primarily concerned with designing a compact Ku-band offset cylindrical reflector antenna for a CubeSat-based Earth Observation mission, with the goal of monitoring Arctic snow and sea ice.
View Article and Find Full Text PDFAdv Healthc Mater
December 2024
Reutlingen University, Alteburgstrasse 150, 72764, Reutlingen, Germany.
Cells can sense geometrical cues with sizes of several tens of micrometers in their vicinity. Recent in vitro studies show that cells can adapt their shape, align along specific directions, or regulate other cellular functions when grown on surfaces with curvatures larger than their size. Although possible mechanisms for such responses like the alignment along axial cues have been suggested, a detailed understanding of the involved cellular processes remains open.
View Article and Find Full Text PDFJ Arachnol
April 2024
University Instrumentation Center, University of New Hampshire, Parsons Hall W123, 23 Academic Way, Durham, New Hampshire 03824, USA.
As in other Palpimanidae, two pairs of posterior spinnerets present in typical Araneomorphae are vestigial in Kulczyński, 1909, with only the anterior lateral spinneret (ALS) pair prominent. Nevertheless, in late juvenile and adult females, spigots appear in the ancestral posterior spinneret region (PS). Consistent with these spigots serving cylindrical silk glands, females construct substantial egg sacs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!