A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Attempt to read property "Count" on bool

Filename: helpers/my_audit_helper.php

Line Number: 3100

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical and angiographic outcomes of axial stent deformations in unrestricted real world patient population. | LitMetric

Background: Prior reports have suggested that the design of the Promus Element stent is prone to longitudinal stent deformation (LSD). However, little is known about the clinical and angiographic outcomes of Promus Element stent axial deformations when implanted in unrestricted coronary lesions.

Method And Results: Two independent reviewers retrospectively evaluated the procedure steps of 961 Promus Element stent (833 de novo lesions in 494 consecutive patients) implanted in unrestricted coronary lesions, between February 2012 and March 2013, and compared the prevalence, predictors, and the mid-term clinical and angiographic outcomes between lesions with and without stent deformation. Fifteen stents (1.56%) with LSD were observed (95% confidence interval [CI]: 0.78-2.34%). The proximal edge of the stent was deformed in 13 stents (86.6%). Ostial stenting (Adjusted Odds ratio [OR]: 9; 95%CI: 2.27-33.3; P = 0.002), and bifurcation lesions (Adjusted OR: 3; 95%CI: 1.03-8.8; P = 0.04) were independently associated with the occurrence of stent deformation. LSD led to unplanned stenting in (53%, 8 of 15) of the deformed stents, which consumed larger contrast volume and longer fluoroscopy time. At 8-month follow-up, there was no significant difference in binary restenosis rate and target lesions revascularization between both groups (P = 0.98, and P = 0.56, respectively), while death occurred in six patients of the non-LSD group (1.36%, 6 of 440) and none in the LSD group. All patients of the LSD group had no major adverse clinical events at 8-month follow-up.

Conclusions: Axial stent deformation in Promus Element platform is an infrequent event, occurs following manipulation of the interventional tools. Other than unplanned stenting, the LSD was not associated with any adverse clinical events at 8-month follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1111/joic.12445DOI Listing

Publication Analysis

Top Keywords

promus element
16
stent deformation
16
clinical angiographic
12
angiographic outcomes
12
element stent
12
stent
9
axial stent
8
deformation lsd
8
implanted unrestricted
8
unrestricted coronary
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!