A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Treatment of refractory ascites with an automated low-flow ascites pump in patients with cirrhosis. | LitMetric

Background: Refractory ascites (RA) is a frequent complication of cirrhosis, requiring large volume paracentesis or placement of a transjugular intrahepatic portosystemic shunt (TIPSS). The automated low-flow ascites pump (alfapump, Sequana Medical AG, Zurich, Switzerland) is an innovative treatment option for patients with RA.

Aim: To assess safety and efficacy of this treatment in patients with a contraindication to TIPSS.

Methods: Fifty-six patients (43 males; mean age 62 years) from centres in Germany, Switzerland, UK and Spain were included and followed for up to 24 months. Complications, device deficiencies, paracentesis frequency and patient survival were recorded.

Results: At the time of this analysis, 3 patients completed the 24-month observation period, monitoring of 3 was ongoing, 9 underwent liver transplantation, 17 patients were withdrawn due to serious adverse events and 23 patients died. Most frequently observed technical complication was blocking of the peritoneal catheter. Twenty-three pump-related reinterventions (17 patients) and 12 pump exchanges (11 patients) were required during follow-up. The pump system was explanted in 48% of patients (in 17 patients due to serious adverse events, in 9 at the time of liver transplantation and in 1 due to recovery from RA). Median frequency of paracentesis dropped from 2.17 to 0.17 per month.

Conclusions: The alfapump can expand therapeutic options for cirrhotic patients with RA. Continuous drainage of ascites in a closed loop automated system led to significant reduction in paracentesis frequency. Technical and procedural improvements are required to reduce the rate of adverse events and reinterventions. https://clinicaltrials.gov/ct2/show/NCT01532427.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5698811PMC
http://dx.doi.org/10.1111/apt.14331DOI Listing

Publication Analysis

Top Keywords

patients
12
adverse events
12
refractory ascites
8
automated low-flow
8
low-flow ascites
8
ascites pump
8
paracentesis frequency
8
liver transplantation
8
serious adverse
8
ascites
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!