Background: Community noise exposure has been shown to increase the risk of hypertension; however, the relationship between occupational noise exposure and hypertension is less clear.

Methods: Using an inception cohort of workers in a specialty metals manufacturing company, we retrospectively assessed occupational noise exposure, hearing acuity, and incident hypertension diagnoses using administrative datasets. Time-weighted average noise exposure levels were assigned to employees based on their job histories. Cox proportional hazards models were performed to determine the association of noise exposure with risk of incident hypertension.

Results: The adjusted hazard ratio (HR) of incident hypertension did not significantly differ between groups by cumulative continuous or categorized noise exposure metric.

Conclusion: We found no increased risk of incident hypertension with exposure to occupational noise among workers. Further assessment examining workers' use of hearing protection devices is warranted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690872PMC
http://dx.doi.org/10.1002/ajim.22775DOI Listing

Publication Analysis

Top Keywords

noise exposure
28
occupational noise
16
incident hypertension
12
exposure
8
exposure risk
8
risk hypertension
8
risk incident
8
noise
7
hypertension
6
occupational
4

Similar Publications

Background: Exposures to hazardous noise causes irreversible injury to the structures of the inner ear, leading to changes in hearing and balance function with strong links to age-related cognitive impairment. While the role of noise-induced hearing loss in long-term health consequences, such as progression or development of Alzheimer's Disease (AD) has been suggested, the underlying mechanisms and behavioral and cognitive outcomes or therapeutic solutions to mitigate these changes remain understudied. This study aimed to characterize the association between blast exposure, hearing loss, and the progression of AD pathology, and determine the underlying mechanisms.

View Article and Find Full Text PDF

Tinnitus prevalence and associations with leisure noise exposure among Canadians, aged 6 to 79 years.

Int J Audiol

January 2025

Environmental Health Science and Research Bureau, Health Canada, Ottawa, Canada.

Objective: To examine the association between individual, cumulative leisure noise exposure (CLNE), acceptable yearly exposure (AYE) and tinnitus among a nationally representative sample of Canadians.

Design: In-person household questionnaires were used to evaluate leisure noise exposure across age, sex, household income and tinnitus: ever experienced, previous year, frequent, bothersome. High (≥85 dBA, LEX), low (<85 dBA, LEX) CLNE and AYEs were defined according to occupational limits.

View Article and Find Full Text PDF

Background: Photon-counting detector (PCD) technology has the potential to reduce noise in computed tomography (CT). This study aimed to carry out a voxelwise noise characterization for a clinical PCD-CT scanner with a model-based iterative reconstruction algorithm (QIR).

Methods: Forty repeated axial acquisitions (tube voltage 120 kV, tube load 200 mAs, slice thickness 0.

View Article and Find Full Text PDF

Landscapers are exposed to noise, carbon monoxide (CO), respirable dust, and respirable crystalline silica (RCS) generated from the tools they use. Although engineering controls are available to reduce these exposures, no previous study has evaluated chronic exposures to landscapers in different work settings and compared exposures from landscaping tools with and without engineering controls. This field study of workers in the landscaping services industry documented the occupational exposures of 80 participants at 11 varied worksites to noise, CO, respirable dust, and RCS using personal breathing zone sampling.

View Article and Find Full Text PDF

Purpose: This study investigated the impact of the field of view (FOV), voxel size, and exposure parameters on the contrast-to-noise ratio (CNR) in cone-beam computed tomography (CBCT).

Materials And Methods: A SedentexCT phantom was scanned using 3D Accuitomo 170 across 3 FOVs (40×40 mm, 60×60 mm, 80×80 mm). Each FOV had 4 settings for kVp and 3 for mA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!