A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of an experimental model of burst fracture with damage characterization of the vertebral bodies under dynamic conditions. | LitMetric

Background: Burst fractures represent a significant proportion of fractures of the thoracolumbar junction. The recent advent of minimally invasive techniques has revolutionized the surgical treatment of this type of fracture. However mechanical behaviour and primary stability offered by these solutions have to be proved from experimental validation tests on cadaveric specimens. Therefore, the aim of this study was to develop an original and reproducible model of burst fracture under dynamic impact.

Methods: Experimental tests were performed on 24 cadaveric spine segments (T11-L3). A system of dynamic loading was developed using a modified Charpy pendulum. The mechanical response of the segments (strain measurement on vertebrae and discs) was obtained during the impact by using an optical method with a high-speed camera. The production of burst fracture was validated by an analysis of the segments by X-ray tomography.

Findings: Burst fracture was systematically produced on L1 for each specimen. Strain analysis during impact highlighted the large deformation of L1 due to the fracture and small strains in adjacent vertebrae. The mean reduction of the vertebral body of L1 assessed for all the specimens was around 15%. No damage was observed in adjacent discs or vertebrae.

Interpretation: With this new, reliable and replicable procedure for production and biomechanical analysis of burst fractures, comparison of different types of stabilization systems can be envisaged. The loading system was designed so as to be able to produce loads leading to other types of fractures and to provide data to validate finite element modelling.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2017.09.007DOI Listing

Publication Analysis

Top Keywords

burst fracture
16
model burst
8
burst fractures
8
burst
6
fracture
6
development experimental
4
experimental model
4
fracture damage
4
damage characterization
4
characterization vertebral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!