Wall shear rate (WSR) is an important stimulus for the brachial artery flow-mediated dilation (FMD) response. However, WSR estimation near the arterial wall by conventional Doppler is inherently difficult. To overcome this limitation, we utilized multigate Doppler to accurately determine the WSR stimulus near the vessel wall simultaneously with the FMD response using an integrated FMD system [Ultrasound Advanced Open Platform (ULA-OP)]. Using the system, we aimed to perform a detailed analysis of WSR-FMD response and establish novel WSR parameters in a healthy young population. Data from 33 young healthy individuals (27.5 ± 4.9 yr, 19 females) were analyzed. FMD was assessed with reactive hyperemia using ULA-OP. All acquired raw data were postprocessed using custom-designed software to obtain WSR and diameter parameters. The acquired velocity data revealed that nonparabolic flow profiles within the cardiac cycle and under different flow states, with heterogeneity between participants. We also identified seven WSR magnitude and four WSR time-course parameters. Among them, WSR area under the curve until its return to baseline was the strongest predictor of the absolute ( R = 0.25) and percent ( R = 0.31) diameter changes in response to reactive hyperemia. For the first time, we identified mono- and biphasic WSR stimulus patterns within our cohort that produced different magnitudes of FMD response [absolute diameter change: 0.24 ± 0.10 mm (monophasic) vs. 0.17 ± 0.09 mm (biphasic), P < 0.05]. We concluded that accurate and detailed measurement of the WSR stimulus is important to comprehensively understand the FMD response and that this advance in current FMD technology could be important to better understand vascular physiology and pathology. NEW & NOTEWORTHY An estimation of wall shear rate (WSR) near the arterial wall by conventional Doppler ultrasound is inherently difficult. Using a recently developed integrated flow-mediated dilation ultrasound system, we were able to accurately estimate WSR near the wall and identified a number of novel WSR variables that may prove to be useful in the measurement of endothelial function, an important biomarker of vascular physiology and disease.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5866444PMC
http://dx.doi.org/10.1152/japplphysiol.00310.2017DOI Listing

Publication Analysis

Top Keywords

wsr stimulus
16
fmd response
16
wsr
13
wall shear
12
shear rate
12
brachial artery
8
multigate doppler
8
healthy young
8
rate wsr
8
flow-mediated dilation
8

Similar Publications

Brachial artery flow-mediated dilation (BAFMD) is induced by hyperemic wall shear rate (WSR) following forearm ischemia. In older adults, there appears to be a reduced brachial hyperemic WSR and altered stimulus-response relationship compared with young adults. However, it is unclear if an altered forearm microvascular response to ischemia influences brachial hyperemic WSR in older adults.

View Article and Find Full Text PDF

Key Points: The vasodilatory response to reactive hyperaemia is impaired with advancing age, but it is unclear whether this is because of an altered wall shear rate (WSR) stimulus or an altered flow-mediated dilatation (FMD) response. Using new technology that allows detailed WSR measurement, we assessed the WSR-FMD response in healthy older people. Our data show that older people have a markedly altered and diminished WSR response to reactive hyperaemia compared to young people, but reduced WSR alone does not fully explain reduced FMD.

View Article and Find Full Text PDF

Vascular ultrasound has been extensively applied in the clinical setting to noninvasively assess the endothelial function by means of the so-called brachial artery flow mediated dilation (FMD). Despite the usefulness in large-scale epidemiological studies, this approach has revealed some pitfalls for assessing vascular physiology and health in individual subjects. Mainly, a reliable FMD examination should be based on the simultaneous and reliable measurement of both the stimulus, i.

View Article and Find Full Text PDF

Wall shear rate (WSR) is an important stimulus for the brachial artery flow-mediated dilation (FMD) response. However, WSR estimation near the arterial wall by conventional Doppler is inherently difficult. To overcome this limitation, we utilized multigate Doppler to accurately determine the WSR stimulus near the vessel wall simultaneously with the FMD response using an integrated FMD system [Ultrasound Advanced Open Platform (ULA-OP)].

View Article and Find Full Text PDF

In flow-mediated dilation (FMD) studies, brachial artery diameter changes due to reactive hyperaemia are typically measured through manual or automatic analysis of high resolution B-mode images while the stimulus of diameter change, i.e., the flow change, is qualitatively estimated by measuring the mean velocity in the vessel and assuming a parabolic velocity profile.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!