Background: Real-time tissue elastography during open hepatectomy facilitates the differential diagnosis of liver tumors by providing information on elasticity. This study investigated the utility of intraoperative real-time tissue elastography (IORTE) during laparoscopic hepatectomy (LH).

Methods: Between 2012 and 2014, IORTE was performed during LH for 21 hepatocellular carcinomas (HCCs), 16 adenocarcinomas and 5 other tumors in 32 patients. The elasticity images were classified into six categories according to the modified criteria on the elasticity type of liver tumors, in which type 1 tumors show more strain than the surrounding liver and type 6 tumors no strain. The concordance of the IORTE findings with those of the pathological examination of the tumors was assessed (The registration no. 1418).

Results: Among the 21 HCCs, 20 were classified as "HCC pattern" (type 3, 4, or 5), resulting in a sensitivity of 95.2%, a specificity of 66.7% and an accuracy of 81.0%. Ten out of the 16 adenocarcinomas were classified as "adenocarcinoma pattern" (type 6), resulting in a sensitivity of 62.5%, a specificity of 92.3% and an accuracy of 81.0%.

Conclusion: IORTE is feasible and provides useful information on the elasticity of liver tumors in LH, in which conventional tumor palpation is difficult.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hpb.2017.08.026DOI Listing

Publication Analysis

Top Keywords

real-time tissue
12
tissue elastography
12
liver tumors
12
intraoperative real-time
8
laparoscopic hepatectomy
8
type tumors
8
tumors strain
8
pattern" type
8
type sensitivity
8
tumors
7

Similar Publications

To investigate the effect of concentrated growth factor (CGF) on the biological performance of human dental pulp stem cells (hDPSCs) under oxidative stress status induced by hydrogen peroxide (HO). The hDPSCs were isolated by using tissue block separation method from healthy permanent teeth extracted for orthodontic reason. hDPSCs surface markers CD34, CD45, CD90 and CD105 were detected by flow cytometry.

View Article and Find Full Text PDF

[Artificial light at night effects glucose metabolism in the developing jawbone by inhibiting melatonin secretion].

Zhonghua Kou Qiang Yi Xue Za Zhi

January 2025

Department of Stomatology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology & School of Stomatology, Tongji Medical College, Huazhong University of Science and Technology & Hubei Province Key Laboratory of Oral and Maxillofacial Development and Regeneration, Wuhan 430022, China.

To investigate the effects of artificial light at night on the growth of mandibles in mice and its regulatory mechanisms. A mouse model of artificial light at night (night light pollution group) and normal lighting (normal light group) was established by controlling light exposure time, with 4 mice in each group. Micro-CT was employed to analyze the differences in bone quantities of the mandibles between the two groups.

View Article and Find Full Text PDF

Development and application of 3D cardiac tissues derived from human pluripotent stem cells.

Drug Metab Pharmacokinet

January 2025

Department of Clinical Regenerative Medicine, Fujita Medical Innovation Center Tokyo, Fujita Health University, Tokyo, Japan; Department of Cardiology, Keio University School of Medicine, Tokyo, Japan. Electronic address:

Recently human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) have become an attractive platform to evaluate drug responses for cardiotoxicity testing and disease modeling. Moreover, three-dimensional (3D) cardiac models, such as engineered heart tissues (EHTs) developed by bioengineering approaches, and cardiac spheroids (CSs) formed by spherical aggregation of hPSC-CMs, have been established as useful tools for drug discovery and transplantation. These 3D models overcome many of the shortcomings of conventional 2D hPSC-CMs, such as immaturity of the cells.

View Article and Find Full Text PDF

Free-Breathing Respiratory Triggered High-Pitch Lung CT: Insights From Phantom and Patient Scans.

Invest Radiol

January 2025

From the Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany (A. Schwarz, A. Simon, A.M.); Siemens Healthineers AG, Forchheim, Germany (A. Schwarz, C.H., J.D., A. Simon); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (F.K.W., S.G., M.S.); and Institut for Radiology, Pediatric and Neuroradiology, Helios Hospital, Schwerin, Germany (H.-J.R.).

Objective: Respiratory motion can affect image quality and thus affect the diagnostic accuracy of CT images by masking or mimicking relevant lung pathologies. CT examinations are often performed during deep inspiration and breath-hold to achieve optimal image quality. However, this can be challenging for certain patient groups, such as children, the elderly, or sedated patients.

View Article and Find Full Text PDF

Purpose: Although mechanical injury to the cornea (e.g. chronic eye rubbing) is a known risk factor for keratoconus progression, how it contributes to loss of corneal integrity is not known.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!