Background: Guidelines on the management of aneurysmal subarachnoid hemorrhage (aSAH) recommend euvolemia, whereas hypervolemia may cause harm. We investigated whether high early fluid input is associated with delayed cerebral ischemia (DCI), and if fluid input can be safely decreased using transpulmonary thermodilution (TPT).

Methods: We retrospectively included aSAH patients treated at an academic intensive care unit (2007-2011; cohort 1) or managed with TPT (2011-2013; cohort 2). Local guidelines recommended fluid input of 3 L daily. More fluids were administered when daily fluid balance fell below +500 mL. In cohort 2, fluid input in high-risk patients was guided by cardiac output measured by TPT per a strict protocol. Associations of fluid input and balance with DCI were analyzed with multivariable logistic regression (cohort 1), and changes in hemodynamic indices after institution of TPT assessed with linear mixed models (cohort 2).

Results: Cumulative fluid input 0 to 72 hours after admission was associated with DCI in cohort 1 (n=223; odds ratio [OR] 1.19/L; 95% confidence interval 1.07-1.32), whereas cumulative fluid balance was not. In cohort 2 (23 patients), using TPT fluid input could be decreased from 6.0 ± 1.0 L before to 3.4 ± 0.3 L; = .012), while preload parameters and consciousness remained stable.

Conclusion: High early fluid input was associated with DCI. Invasive hemodynamic monitoring was feasible to reduce fluid input while maintaining preload. These results indicate that fluid loading beyond a normal preload occurs, may increase DCI risk, and can be minimized with TPT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6927070PMC
http://dx.doi.org/10.1177/0885066617732747DOI Listing

Publication Analysis

Top Keywords

fluid input
40
fluid
14
high early
12
early fluid
12
input
10
aneurysmal subarachnoid
8
subarachnoid hemorrhage
8
delayed cerebral
8
cerebral ischemia
8
input associated
8

Similar Publications

Mechanical force attracts booming attention with the potential to tune the tumor cell behavior, especially in cell migration. However, the current approach for introducing mechanical input is difficult to apply in vivo. How the mechanical force affects cell behavior in situ also remains unclear.

View Article and Find Full Text PDF

Protecting monoclonal antibodies via competitive interfacial adsorption of nonionic surfactants.

J Colloid Interface Sci

December 2024

Biological Physics Laboratory, Department of Physics and Astronomy, University of Manchester, Oxford Road, Schuster Building, Manchester M13 9PL, UK. Electronic address:

Hypothesis: Bioengineered monoclonal antibodies (mAbs) have gained significant recognition as medical therapies. However, during processing, storage and use, mAbs are susceptible to interfacial adsorption and desorption, leading to structural deformation and aggregation, and undermining their bioactivity. To suppress antibody surface adsorption, nonionic surfactants are commonly used in formulation.

View Article and Find Full Text PDF

New flow control elements in capillaric circuits are key to achieving ever more complex lab-on-a-chip functionality while maintaining their autonomous and easy-to-use nature. Capillary field effect transistors valves allow for flow in channels to be restricted and cut off utilising a high pressure triggering channel and occluding air bubble. The reversible capillary field effect transistor presented here provides a new element that can restore fluid flow in closed microchannels autonomous circuit feedback.

View Article and Find Full Text PDF

A study on hybrid-architecture deep learning model for predicting pressure distribution in 2D airfoils.

Sci Rep

January 2025

School of Aerospace Engineering, Gyeongsang National University, Jinju-si, 52828, Gyeongsangnam-do, Republic of Korea.

This study introduces a novel deep learning-based technique for predicting pressure distribution images, aimed at application in image-based approximate optimal design. The proposed approach integrates both unsupervised and supervised learning paradigms, employing autoencoders (AE) for the unsupervised component and fully connected neural networks (FNN) for the supervised component. A surrogate model based on 2D image data was developed, enabling a comparative analysis of three distinct methods: the conventional AE, the convolutional autoencoder (CAE), and a hybrid CAE, which combines the CAE with a conventional AE.

View Article and Find Full Text PDF

A low-cost soft sensor for sewer flow monitoring - Learning from water level measurements in manholes.

Water Res

January 2025

School of Energy and Environment, City University of Hong Kong, Hong Kong SAR, China; State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong SAR, China. Electronic address:

Flow meters are commonly used in manholes to monitor the flow rate for sewer operation and management. However, the large-scale deployment of flow meters in a sewer system is cost-prohibitive due to their high costs and the need for frequent maintenance. This paper proposes a soft sensor that estimates flow rates based on water level measurements in a manhole.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!