Background: Improvements in pain, function, and patient satisfaction are used to evaluate the outcomes of hip arthroscopic surgery.

Purpose: To identify correlations between the visual analog scale (VAS) score for pain and patient satisfaction with 4 commonly used patient-reported outcome (PRO) scores to determine to what extent changes in these 2 parameters are reflected in each of the PRO scores.

Study Design: Cohort study (diagnosis); Level of evidence, 3.

Methods: Patients undergoing hip arthroscopic surgery between February 2008 and February 2013 were assessed prospectively before surgery, at 3 months, and annually thereafter with the modified Harris Hip Score (mHHS), Nonarthritic Hip Score (NAHS), Hip Outcome Score-sports-specific subscale (HOS-SSS), and Hip Outcome Score-activities of daily living (HOS-ADL). Patients were also assessed using a 10-point VAS for pain and queried for satisfaction at the same time points ("0" indicated no pain, and "10" indicated complete satisfaction with surgery). The VAS score and patient satisfaction were correlated with changes in the 4 PRO scores.

Results: During the study period, 1417 patients underwent hip arthroscopic surgery, of whom 1137 patients had 2-year postoperative PRO scores after primary surgery. There was a significant improvement in all PRO scores at 2-year follow-up. The mean improvements in mHHS, NAHS, HOS-ADL, and HOS-SSS scores were 16.7, 21.6, 19.7, and 22.7 points, respectively. The mean improvement in the VAS score was 2.9 points. Mean patient satisfaction at 2-year follow-up was 7.74 (of 10). There was a statistically significant correlation between the VAS and patient satisfaction scores and changes in each of the 4 PRO scores. The strength of the correlation was moderate.

Conclusion: This study demonstrated a moderate correlation between the VAS and patient satisfaction outcomes and changes in 4 commonly used PRO scores in hip arthroscopic surgery (mHHS, HOS-ADL, HOS-SSS, and NAHS). In addition to several PRO instruments, a VAS for pain and patient satisfaction may add to the overall assessment of the efficacy of hip arthroscopic surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5600309PMC
http://dx.doi.org/10.1177/2325967117724772DOI Listing

Publication Analysis

Top Keywords

patient satisfaction
32
hip arthroscopic
24
arthroscopic surgery
20
pro scores
20
vas score
12
satisfaction
10
hip
10
visual analog
8
analog scale
8
patient-reported outcome
8

Similar Publications

Background: CT-P47 is a candidate tocilizumab biosimilar that is currently in clinical development. We assessed the usability of CT-P47 self-administration via auto-injector (AI) in patients with rheumatoid arthritis (RA).

Research Design And Methods: This was a 12-week, single-arm, open-label, multiple-dose, Phase 3 study.

View Article and Find Full Text PDF

This study aims to identify factors influencing aesthetic outcomes following facial basal cell carcinoma (BCC) plastic surgery to enhance post-operative satisfaction and cosmetic results. A retrospective cohort study was conducted on 303 patients who underwent facial BCC plastic surgery between June 2021 and June 2023. Data on demographics, blood tests, SF-12, and Skindex-16 scores were analyzed.

View Article and Find Full Text PDF

Overcrowding in emergency departments (EDs) is a global challenge, leading to prolonged waiting times and adverse patient outcomes. Telemedicine has emerged as a promising solution, enabling remote consultation, triage, and real-time specialist input. Despite its growing application, limited systematic research exists on its specific role in ED triage and care.

View Article and Find Full Text PDF

Tendon Transfer Procedures for Correction of Foot Drop Due to Injury to the Peripheral Nerves or Muscles.

J Brachial Plex Peripher Nerve Inj

January 2025

Department of Hand, Plastic, Reconstructive and Burn Surgery, BG Klinik Tuebingen, University of Tübingen, Tübingen, Germany.

 Foot drop is a challenging condition that significantly impacts the affected patient's mobility and quality of life. Tendon transfer has emerged as a viable treatment option. We hereby present data of the tendon transfer procedures in patients with foot drop in our department.

View Article and Find Full Text PDF

A Comparative Study of the Use of a 980 nm Diode Laser and 10600nm CO2 in the Treatment of Gingival Melanin Pigmentation.

J Lasers Med Sci

December 2024

Department of Periodontics, Dental Implants Research Center, Dental Research Institute, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.

Gingival depigmentation with the help of lasers is known as an effective technique. The aim of this study was to compare the efficiency of 980nm diode and CO2 lasers in the treatment of gingival hyperpigmentation. In this clinical trial study, 14 individuals (8 females and 6 males) with the age range of 19 to 47 years were selected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!