Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Arterial blood pressure is the most common variable used to assess the response to a fluid challenge in routine clinical practice. The aim of this study was to evaluate the accuracy of the change in the radial artery pulse pressure (rPP) to detect the change in cardiac output after a fluid challenge in patients with septic shock.
Methods: Prospective observational study including 35 patients with septic shock in which rPP and cardiac output were measured before and after a fluid challenge with 400 mL of crystalloid solution. Cardiac output was measured with intermittent thermodilution technique using a pulmonary artery catheter. Patients were divided between responders (increase >15% of cardiac output after fluid challenge) and nonresponders. The area under the receiver operating characteristic curve (AUROC), Pearson correlation coefficient and paired Student test were used in statistical analysis.
Results: Forty-three percent of the patients were fluid responders. The change in rPP could not neither discriminate between responders and nonresponders (AUROC = 0.52; [95% confidence interval: 0.31-0.72] = .8) nor correlate ( = .21, = .1) with the change in cardiac output after the fluid challenge.
Conclusions: The change in rPP neither discriminated between fluid responders and nonresponders nor correlated with the change in cardiac output after a fluid challenge. The change in rPP cannot serve as a surrogate of the change in cardiac output to assess the response to a fluid challenge in patients with septic shock.