Background: To study biometric and structural ocular manifestations of Marfan syndrome (MFS).

Methods: Observational, retrospective, comparative cohort study in a tertiary referral center on 285 MFS patients and 267 controls. Structural and biometric ocular characteristic were compared.

Results: MFS eyes were longer (axial length 24.25 ± 1.74 mm versus 23.89 ± 1.31 mm, p < 0.001) and had a flatter cornea than control eyes (mean keratometry 41.78 ± 1.80 diopters (D) versus 43.05 ± 1.51 D, p < 0.001). Corneal astigmatism was greater and the central cornea was thinner in MFS eyes (530.14 ± 41.31 μm versus 547.02 ± 39.18 μm, p < 0.001). MFS eyes were more myopic than control eyes (spherical equivalent -2.16 ± 3.75 D versus -1.17 ± 2.58 D, p < 0.001). Visual acuity was reduced (0.13 ± 0.25 logMAR versus 0.05 ± 0.18 logMAR, p < 0.001) and intraocular pressure was lower in MFS eyes (14.6 ± 3.4 mmHg versus 15.1 ± 3.2 mmHg, p = 0.01). Iris transillumination defects (ITD) were significantly more common in MFS eyes (odds ratio for MFS in the presence of ITD, 3.7). Ectopia lentis (EL) was only present in MFS eyes (33.4%). History of retinal detachment was significantly more common in MFS eyes. Glaucoma was equally common in both groups.

Conclusions: ITD and EL are most characteristic findings in MFS. ITD and corneal curvature should be studied as diagnostic criteria for MFS. Visual acuity is reduced in MFS. MFS patients need regular eye exams to identify serious ocular complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5607136PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0183370PLOS

Publication Analysis

Top Keywords

mfs eyes
28
mfs
13
eyes
9
biometric structural
8
structural ocular
8
ocular manifestations
8
manifestations marfan
8
marfan syndrome
8
mfs patients
8
control eyes
8

Similar Publications

Marfan syndrome: insights from animal models.

Front Genet

January 2025

Sichuan Provincial Key Laboratory for Genetic Disease, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China.

Marfan syndrome (MFS) is an inherited disorder that affects the connective tissues and mainly presents in the bones, eyes, and cardiovascular system, etc. Aortic pathology is the leading cause of death in patients with Marfan syndrome. The fibrillin-1 gene () is a major gene involved in the pathogenesis of MFS.

View Article and Find Full Text PDF

Purpose: To evaluate the prognosis of eyelid sebaceous carcinoma (SeC) in patients with disease stage worse than IIA.

Methods: This retrospective, single-center study included 78 SeC patients. For stage II patients, 1:3 propensity score matching (PSM) was applied between those undergoing orbital exenteration and those receiving eye-sparing treatments.

View Article and Find Full Text PDF

Miller Fisher syndrome (MFS) is a rare Guillain-Barré syndrome (GBS) variant. The global incidence of GBS is approximately one to two in 100,000 children (aged 0 to 15 years) per year. Miller Fisher syndrome represents a further small subset, with the incidence being one to two in 1,000,000 children.

View Article and Find Full Text PDF

Introduction: Presbyopia, difficulty in seeing close-ups, affects a billion people globally. Mobile financial services (MFS) have been mandated since January 2021 for Bangladesh government social safety net payments, including old age allowance (OAA) and widow allowance (WA). We report the protocol for the Transforming Households with Refraction and Innovative Financial Technology randomised trial assessing the impact on the use of online banking of providing presbyopic safety net beneficiaries with reading glasses, and brief smartphone and mobile banking app training.

View Article and Find Full Text PDF

Improving the Accuracy of Lens Formulas for in-the-bag Intraocular Lens Implantation in Marfan Syndrome Patients with Ectopia Lentis.

J Cataract Refract Surg

December 2024

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200031, China.

Purpose: To improve the accuracy of intraocular lens (IOL) power calculation formulas by modifying the effective lens position (ELP) equations for patients with Marfan Syndrome (MFS) and ectopia lentis (EL) undergoing in-the-bag IOL implantation.

Setting: Eye and ENT Hospital of Fudan University.

Design: Retrospective cohort study.